Whirlpool AWZ 126 Panduan Servis - Halaman 2
Jelajahi secara online atau unduh pdf Panduan Servis untuk Pengering Whirlpool AWZ 126. Whirlpool AWZ 126 8 halaman. Tumble dryer. air vent
02.04.1997 / Page 2
Doc. No: 4812 713 11036
Technical data
Dimensions
Height
Width
Depth
Weight
Gross weight
Net weight
Surroundings temperature
Max.room temperature
Min. room temperature
Humidity
Max. relative humidity
Power connection
Voltage
Frequency
Connected load
Fuse
Drum data
Volume
Drum speed (empty)
Airflow
Maximum loading capacity
Cotton
Easy care
Exhaust hose
Inner diameter
Maximum allowable
(with 2 bows)
Electrical components
Heating
Type
Nominal voltage
Nominal power
Resistor R 20
85,0
cm
59,5
cm
56,0
cm
33
kg
31
kg
35
˚C
5
˚C
95
%
220
V
60
Hz
2,2
kW
10
A
104
l
56 ± 3
rpm
3
120 - 160 m
/h
5
kg
2,5
kg
10
cm
4
m
Aluminium mass
heating
230
V
2050± 5%W
Ω
23,5-28
Whirlpool Europe
Customer Service
Thermostats
Safety thermostat(in heater) TL
Switch off temperature
Fluff thermostat (in heater) TH 1.2
Switch on temperature
Switch off temperature
Exhausting thermostat (in bottom) TH 1.1
Switch on temperature
Switch off temperature
Timer
Type
Nominal voltage
Frequency
Number of steps
- Stop
- Heating (173 min)
- Cool down (6 min)
- Anticreasing (13 min)
- Stop
Ambient temperature
Storage temperature
Main- and blower motor
Type
Nominal voltage
Frequency
Power consumption
Resistances of coils
Main coil (2-3)
Auxiliary coil (2-1)
Rated speed with 5kg
laundry and 100 % rest
humidity
Capacitor
S E R V I C E
270 ± 10 ˚C
180 ± 7 ,5 ˚C
205 ± 7 ,5 ˚C
45 ± 5
˚C
60 ± 4
˚C
electromechanical
Timer, Eaton
EC 4511
220
V
60
Hz
60
01
02 - 53
54 - 55
56 - 59
60
up to 70 ˚C
up to 85 ˚C
1-phase asynchronous
220
V
60
Hz
295± 7% W
21,5± 7% Ω
21,5± 7% Ω
2750
rpm
10± 10% µ F