Whirlpool Centennial MEDC700 Panduan Petunjuk Instalasi - Halaman 9
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Pengering Whirlpool Centennial MEDC700. Whirlpool Centennial MEDC700 16 halaman. 27" wide models - u.s.a. only
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go
to "Venting Requirements."
4-wire connection: Direct Wire
ImPoRTAnT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5" (127 mm). Cut 1½" (38 mm) from
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends
of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1. Remove center, silver-colored terminal block screw (B).
2. Remove neutral ground wire (E) from external ground
conductor screw (A).
3. Connect neutral ground wire (E) and place the hooked end
(hook facing right) of the neutral wire (C) (white or center wire)
of direct wire cable under the center screw of the terminal
block (B). Squeeze hooked ends together. Tighten screw.
4. Connect ground wire (F) (green or bare) of direct wire cable to
external ground conductor screw (A). Tighten screw.
5. Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
E
B
A
6. Tighten strain relief screw.
7. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
8. You have completed your electrical connection. Now go
to "Venting Requirements."
A
F
B
C
E
9