Whirlpool CSP2760TQ3 Panduan Petunjuk Instalasi - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Pengering Whirlpool CSP2760TQ3. Whirlpool CSP2760TQ3 36 halaman. Commercial stacked dryer gas (120-volt,60-hz)or electric (120/240-volt,60-hz)

Direct Wire
Method
- U.S. Only
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical
shock.
Direct wire cable must match power supply (4-wire or 3-wire)
and be:
[]
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit.
All current-carrying
wires must be insulated.
[]
10-gauge solid copper wire (do not use aluminum).
[]
At least 5 ft. (1.52 m) long.
1. Disconnect power.
2=
Remove hold-down screw and terminal block cover.
A........
0
J
3=
A. External ground conductor screw
B. Tab
C. Terminal block cover
D. Hold-down screw
Install ,_A"conduit connector into the hole below the terminal
block opening. Connect flexible metallic conduit and tighten
connector screw. Install direct wire cable through the flexible
metallic conduit.
L_
J
4=
A. Conduit connector
B. Dryer cabinet
C. Connector screw
Complete installation following instructions for your type of
electrical connection:
Four-wire (recommended method)
Three-wire (if four-wire is not available)
Direct Wire,
Four=wire electrical
connection:
5" (127 mm)
Strip 5" (127 mm) of outer covering
from end of cable. Leave green or bare
Shape ends
ground wire at 5" (127 mm). Cut I_A"
of wires into
(38 mm) from 3 remaining wires. Strip
a hook.
insulation back 1" (25 mm).
A. s/4" ( 19mm) conduitconnector
B. Neutral(whiteor center)
C. Groundwire (greenor bare)
D. lO-gauge,3 wirewith groundwire
in flexiblemetallicconduitO
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground
wire from the external ground conductor
screw. Fasten under center, silver-
colored terminal block screw.
7. Connect the ground wire (green or bare)
of the direct wire cable to the external
ground conductor screw. Tighten screw.
8. Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze hook
end together. Tighten screw.
9. Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
10. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
F
g
c
D
A. External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Neutral (center wire)
F. Green or bare ground wire
14