Dryer gas pipe
•
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
3. Open the shutoff valve in the supply line. The valve is open when
the handle is parallel to the gas pipe.
........
_
1½"
A
(38ram}
A. 1/2" NPT gas supply line
B. 3/8" NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe
height must be an additional 10" (254 mm) or 15.5" (394 mm)
from the floor, depending on the pedestal model. For a garage
installation, the gas pipe height must be an additional
18" (460 mm) from the floor.
1.
2.
Make Gas Connection
Remove the red cap from the gas pipe.
Using a wrench to tighten, connect the gas supply to the dryer.
Use pipe-joint compound on the threads of all non-flared male
fittings. If flexible metal tubing is used, be sure there are no kinks.
...................
g
A. Flared male fitting
B. Non-flared male fitting
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to the action of LP gas. Do not use
TEFLON °t tape.
A combination of pipe fittings must be used to connect the dryer
to the existing gas line. Shown is a recommended connection.
Your connection may be different, according to the supply line
type, size and location.
/
f
A
\
B
\
C
A. 3/8" flexiblegas
C. 3/8" to 3/8" pipe elbow
connector
D. 3/8" pipe-to-flare
B 3/8" dryerpipe
adapter fitting
4.
A. Closed valve
B. Open valve
Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leak found.
VENTING
Venting Requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used
for exhausting.
If using an existing vent system
•
Clean lint from the entire length of the system and make
sure exhaust hood is not plugged with lint.
•
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
•
Review vent system chart. Modify existing vent system
if necessary to achieve the best drying performance.
t®TEFLON
is a registered trademark
of E.I. Du Pont De Nemours and Company.