Location Requirements

Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
You will need:
A separate 30-amp circuit.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If forward slope is greater than 1" (25 mm), water
could run out from front of filter. If not level, clothes may
not tumble properly and automatic sensor cycles may
not operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above floor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
40°F (4°C). Lower temperatures may cause dryer not to shut
off at end of automatic sensor cycles, resulting in longer
drying times.
DRYER DIMENSIONS
Front view:
33
1
" Min.
33
/
" Min.
1
2
2
(851 mm)
(851 mm)
33
/
" Max.
1
3
34
" Max.
4
2
(857 mm)
(876 mm)
24"
24"
(610 mm)
(610 mm)
Side view:
43
5
"
41
/
"
1
16
2
(1100 mm)
(1054 mm)
3
/
(18 mm)
Back view:
NOTES:
Allow clearance
behind dryer for
proper drain hose
routing and cooling
fan ventilation. Push
dryer back as far as
possible and make
sure drain hose
is not crushed
or kinked.
7
1
/
"
4
Water can be
(184 mm)
drained into an
alternate location.
Remove the top
end of the white
hose from the water
tank and install,
for example, in
a floor standpipe
(see "Drain
System").
IMPORTANT: Do not block cooling fan as your dryer may not
operate properly.
26"
24"
(654 mm)
(610 mm)
"
4
White hose from pump
to water tank
Cooling
fan
Power cord/
cable
4"
(102 mm)
(18 mm)
Grey
water
drain
/
"
3
4
15