Whirlpool 30 " Eye-Level Gas Range Panduan Petunjuk Instalasi - Halaman 20

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Kap Ventilasi Whirlpool 30 " Eye-Level Gas Range. Whirlpool 30 " Eye-Level Gas Range 48 halaman. Freestanding gas range with self-cleaning oven
Juga untuk Whirlpool 30 " Eye-Level Gas Range: Petunjuk Pemasangan Dan Panduan Penggunaan Dan Perawatan (32 halaman), Panduan Petunjuk Instalasi (11 halaman), Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan (28 halaman), Panduan Petunjuk Instalasi (11 halaman), Petunjuk Instalasi (5 halaman), Panduan Petunjuk Instalasi (28 halaman), Panduan Petunjuk Instalasi (32 halaman), Panduan Petunjuk Instalasi (12 halaman), Petunjuk Instalasi (5 halaman), Panduan Petunjuk Instalasi (7 halaman), Panduan Instalasi (7 halaman), Panduan Petunjuk Instalasi (7 halaman), Petunjuk Instalasi (5 halaman), Panduan Petunjuk Instalasi (7 halaman), Panduan Petunjuk Instalasi (10 halaman)

Whirlpool 30
3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap counterclockwise with a ⁵⁄₈"
(1.6 cm) combination wrench to remove.
NOTE: Do not remove the spring beneath the cap.
A
B
C
A. Plastic cover
B. Gas pressure regulator cap with hollow end facing out
C. Gas pressure regulator cap with solid end facing out
D. Washer
E. Gas pressure regulator cap
5. Turn over the gas pressure regulator cap and reinstall on
regulator so that the solid end faces out and the marking
"
NG" is facing the direction shown in the above drawing.
6. Replace plastic cover over gas pressure regulator cap.
To Convert Surface Burners (LP Gas to Natural Gas)
1. Remove burner cap.
2. Remove the burner base.
A
A. Igniter electrode
B. Burner cap
C. Gas tube opening
D. Burner base
20
Side view before
D
E
Side view after
B
C
D
3. Apply masking tape to the end of a 7 mm (⁹⁄₃₂") nut driver to
help hold the gas orifice spud in the nut driver while changing
it. Press nut driver down onto the gas orifice spud and
remove by turning it counterclockwise and lifting out. Set gas
orifice spud aside.
B
A
C
A. Igniter electrode
B. Orifice spud
C. Orifice spud holder
D. Screws
4. Gas orifice spuds are stamped with a number on the side.
Replace the LP gas orifice spud with the correct Natural gas
orifice spud.
A. Stamped number
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart⁰
Burner Rating
Color
19,000 BTU (ST)
White/Gray
17,000 BTU (ST)
N/A
17,000 BTU
White/Blue
15,000 BTU
White/Green
9,200 BTU
White/Black
8,000 BTU
White/Yellow
5,000 BTU
White/Orange
1,200 BTU
Black
NOTE: Refer to the Model Number and Serial Number Plate
located on the oven frame behind the top right side of the oven
door for proper sizing of spuds for each burner location.
5. Place LP gas orifice spuds in the orifice spud bag.
IMPORTANT: Keep the LP gas orifice spuds in case of
reinstallation with LP gas.
6. Replace the burner base.
7. Replace burner cap.
8. Repeat steps 1-7 for the remaining burners.
D
A
Size (mm) ID Number
1.84
184
1.75
175
1.90
190
1.80
180
1.35
135
1.25
125
1.00
100
0.52
52