Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP Petunjuk Pemasangan Dan Panduan Penggunaan Dan Perawatan - Halaman 5
Jelajahi secara online atau unduh pdf Petunjuk Pemasangan Dan Panduan Penggunaan Dan Perawatan untuk Kap Ventilasi Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP. Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP 28 halaman. 36" (91.4 cm) island-mount canopy range hood
Juga untuk Whirlpool 36" (91.4 CM) GAS BUILT-IN COOKTOP: Panduan Petunjuk Instalasi (16 halaman), Panduan Penggunaan & Perawatan (32 halaman)
Installation dimensions
12"
(30.5 cm)
¹⁄₂
10
" (26.7 cm)
12"
(30.5 cm)
side
cabinet
36" (91.4 cm)
minimum
centerline
Venting Requirements
Vent system must terminate to the outside.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended. Do not
use plastic or metal foil vent.
For the most efficient and quiet operation:
■ Use a straight run or as few elbows as possible.
■ Use no more than three 90° elbows.
■ Make sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than one elbow is used.
■ Do not install two elbows together.
■ Use duct tape to seal all joints in the vent system.
■ Use caulking to seal exterior wall or roof opening around
the cap.
Cold weather installations
An additional backdraft damper should be installed to minimize
backward cold air flow and a nonmetallic thermal break to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Make-up air
Local building codes may require the use of make-up air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
2" (50.1 mm)
min.
vent and power
supply cable entry
location
21"
(53.3 cm)
min.
side
cabinet
30" (76.2 cm) min.
bottom of canopy to
cooking surface
Venting methods
This canopy hood is factory set for venting through the roof or
wall.
An 8" (20.3 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 8" (20.3 cm) round.
Vent system can terminate either through the roof or wall. To vent
through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For non-vented (recirculating) installations
Should it not be possible to vent cooking fumes and vapors to
the outside, the hood can be used in the non-vented
(recirculating) version, fitting an activated carbon filter and the
deflector, fumes and vapors are recycled through the top grille.
roof cap
8"
8"
(20.3 cm)
(20.3 cm)
round vent
round vent
Roof venting
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent piece
45° elbow
90° elbow
Maximum equivalent vent length is 50 feet (15.2 meters).
90° elbow
6 ft. (1.8 m)
1 — 90° elbow
2 ft.
(0.6 m)
8 ft. (2.4 m) straight
1 — wall cap
system length
deflector
wall
cap
8"
(20.3 cm)
round vent
Wall venting
Non-vented
(recirculating)
8" (20.3 cm) round
2.5 feet
(0.8 m)
5.0 feet
(1.5 m)
wall cap
Example vent
system
=
5 ft. (1.5 m)
=
8 ft. (2.4 m)
=
0 ft.
(0 m)
= 13 ft. (3.9 m)
5