Whirlpool 9760266 Petunjuk Pemasangan Dan Panduan Penggunaan Dan Perawatan - Halaman 4

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan Dan Panduan Penggunaan Dan Perawatan untuk Kap Ventilasi Whirlpool 9760266. Whirlpool 9760266 28 halaman. 30" (76.2 cm) and 36" (91.4 cm) wall-mount canopy range hood

Whirlpool 9760266 Petunjuk Pemasangan Dan Panduan Penggunaan Dan Perawatan

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Tools needed:
level
drill with 1 " (3 cm),
" (9.5 mm),
" (3 mm) drill bits
pencil
wire stripper or utility knife
measuring tape or ruler
pliers
caulking gun and weatherproof caulking compound
duct tape
jig saw or keyhole saw
flat blade screwdriver
metal snips
Phillips screwdriver
Parts needed:
1 x
" conduit
1 wall or roof cap
metal vent system
2 charcoal filters – for non-vented (recirculating)
installations only
Parts supplied:
Remove parts from packages. Check that all parts were included.
hood canopy assembly with ventilator and light bulbs installed
deflector for non-vented (recirculating) installations
plastic transition with back draft dampers installed
Installation Instructions and Use & Care Guide
filter(s) – depending on model and size
screws and drywall anchors
2 mounting hooks
vent cover support bracket
mounting template
2 piece vent cover
rubber tape
4

INSTALLATION REQUIREMENTS

" (2.75 mm) and

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) installations see "Non-vented
(recirculating) installations" in "Prepare Mounting Location"
section.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
Product Dimensions
8"
(20.3 cm)
6 "
(17.1 cm)
upper vent
cover
lower vent
cover
20
"
(51.3 cm)
NOTE: For reduced ceiling height vented and non-vented (recirculating)
installations, only the upper vent cover, which is 26" (66.0 cm), is used.
9 " (24.4 cm) min.
26" (66.0 cm) max.
26" (66.0 cm)
min.
42 " (107.6 cm)
16 "
max.
(42.5 cm)
9 "
(24.1 cm)
30" (76.2 cm) or
36" (91.4 cm)