Whirlpool GZ5730XRS1 Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan - Halaman 8

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan untuk Kap Ventilasi Whirlpool GZ5730XRS1. Whirlpool GZ5730XRS1 24 halaman. 30" (76.2 cm) and 36" (91.4 cm) convertible range hood
Juga untuk Whirlpool GZ5730XRS1: Manual Suku Cadang (1 halaman)

Whirlpool GZ5730XRS1 Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan
g,
Remove either top or rear rectangular knockout, if using 7"
(17.8 cm) round vent, remove both top rectangular knockout
and the semi-circular knockout.
Direct
Wiring
installation
--- __.
A. Semi-circular k nockout
B. Toprectangular k nockout
C. Rearrectangular k nockout
10, install damper:
Vortical vent
position
B
Horizontal vent
position
A. Up to 1" (2.5 cm) side-to-side adjustment
B. Pivot
C. Damper/vent connector
Rectangular
vent only:
Attach damper/vent
connector over knockout opening. Make
sure damper pivot is nearest to top/back edge of hood,
Remove tape from damper flap.
NOTE: For horizontal vent systems, it is recommended that
the rectangular ventwork be attached to the damper/vent
connector and sealed with duct tape before installing the
hood.
Round vent only:
Replace round vent plate removed in step 1 of "Prepare the
Hood" section.
Install a 7" (17.8 cm) round damper (must be purchased
separately). The damper flap must open freely in the direction
of air flow (away from range hood),
NOTE: Damper/vent connector and round vent plate can be
installed up to 1" (2.5 cm) on either side of hood center if
ventwork is off-center, in extreme off-center installations, one
end of the vent connector may need to be trimmed to clear
the electrical strain relief.
Electdcam Shock Hazard
Disconnect
power before servicing.
Replace all parts and panems before operating.
Failure to do so can resuJt in death or emectrical shock,
EmectdcaI Shock Hazard
Electrically
ground the blower.
Connect ground
wire to green ground screw in
wiring box.
Paimure to do so can resumt in death or eiectricam shock.
1, Disconnect power.
2, If not previously done, run wiring through wall or cabinets
according to electrical codes and ordinances,
3, Stand hood up as shown, (Keep on protective cover to
protect hood and cooking sudace,) Feed the power supply
cable through the strain relief.
F
i_ ¸
,
©
4, Use twist-on connectors and connect black wires together.
5, Use twist-on connectors and connect white wires together.