Whirlpool GZ7930XH Panduan Dimensi

Jelajahi secara online atau unduh pdf Panduan Dimensi untuk Kap Ventilasi Whirlpool GZ7930XH. Whirlpool GZ7930XH 1 halaman. Retractable downdraft vent system

Whirlpool GZ7930XH Panduan Dimensi
®
PRODUCT MODEL NUMBERS
GZ7930XG
GZ7936XG
GZ7930XH
GZ7936XH
Electrical: 120-volt, 60-Hz, AC-only, 15 amp
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.
16"
(40.6 cm)
EXTERIOR-MOUNTED
BLOWER MOTOR
For use with
Model No. KPEC992M
[900 cfm (25.5 m3/m)]
only
9" (22.9 cm)
Diameter
CABINET OPENING DIMENSIONS
See cooktop manufacturer's
instructions for cooktop cutout
depth and width.
Use dimensions for vent system
cutout location that applies to
your installation.
A = 1/2" (12.7 mm)
min.
17-3/16"
(43.7 cm)
all cutouts shown are
for 3-1/4" x 10"
(8.3 cm x 25.4 cm)
vent system
Locate power supply
junction box at lower
right hand rear corner of
cabinet.
Vent system cutout dimensions for internal blower models only.
Exterior mounted blower systems connect with 10" (25.4 cm) round vent. The cutout
locations for this vent system will depend upon your specific installation.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Retractable Downdraft Vent System
OVERALL DIMENSIONS
8"
(20.3 cm)
8"
(20,3 cm)
16"
(40.6 cm)
23-9/16"
(59.8 cm)
3/8"
(9.5 mm)
centerline of
cooktop cutout
4"
27" (68.6 cm) for 30" (76.2 cm) vent
(10.2 cm)
33" (83.8 cm) for 36" (91.4 cm) vent
3-1/4"x 10"
(8.3 cm x 25.4 cm)
16"
(40.6 cm)
5/8"
(15.9 mm)
16"
(40.6 cm)
4-1/8"+A
(10.5 cm)
17-9/16"
(44.6 cm)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
top trim widths
30" vent (76.2 cm)
36" vent (91.4 cm)
8-1/4" (21 cm)
retractable
vent height
INTERNAL
BLOWER
MOTOR
9-3/8"
(23.8 cm)
Maximum length of vent system
Vent
6" (15.2 cm) round
3-1/4" x 10"
(8.3 cm x 25.4 cm)
For best performance, use no more than
three 90° elbows. If more than one elbow
is used, make sure that there is a
minimum of 24" (61 cm) of straight vent
between any two elbows. Do Not install
two elbows together. It is recommended
that you use round vent instead of
rectangular vent, especially if elbows are
required. If rectangular vent is required,
it should be transitioned to 6" (15.2 cm)
round vent as soon as possible.
Determining the length of system
you need:
To calculate the length of system you
need, add the equivalent feet for each
vent piece that will be needed. See
example for 6" (15.2 cm) round vent
system.
1-1/2"
(3.8 cm)
3/8" (9.5 mm)
26-1/8"
(66.4 cm)
5/8"
(15.9 mm)
2-1/8"
(54 cm)
Length
35 feet (8.9 m)
35 feet (8.9 m)
Ref. 8284826 Rev. B
10-20-03