FRONT PANEL REMOVAL
1. Remove
the three screws
that secure
the front panel;
lower and remove front panel.
2. This appliance
is equipped
with copper
lead wires.
If
connection
is made to aluminum
house wiring,
use only
special
connectors
which are approved
for joining
copper
and
aluminum
wires
in accordance
with
the
National
Electrical
Code and local codes and ordinances.
FRONT PANEL
SWITCH KNOBS
\
\
b
PANEL SCREWS
\
Q+
HOOD FLANGE
FRONT
;ANEL
Figure
10
PROVIDING
ELECTRICAL
POWER
IT IS THE PERSONAL
RESPONSIBILITY
AND OBLIGA-
TION OF THE CUSTOMER
TO CONTACT
A QUALIFIED
INSTALLER
TO ASSURE
THAT
THE
ELECTRICAL
IN-
STALLATION
IS ADEQUATE
AND IS IN CONFORMANCE
WITH THE NATIONAL
ELECTRICAL
CODE AND LOCAL
CODES AND ORDINANCES.
1. Connect
the wiring
to the junction
box through
flexible
armoured
or nonmetallic
sheathed
copper
cable
(with
REMOVE
7/8"DlA
KNOCK
OUT
FOR
WIRING
TO JUNCTION
80X
--
.~
RECEPTACLE
tot-
//<Z
Y&c.
Figure
11
ground
wire). A suitable
strain relief must be provided
at
each end of the power supply cable (at appliance
and at the
junction
box.
. . 8
Figure
12
Electrical
Ground
is Required
on This Appliance
Recommended
Electrical
Connection
and Grounding
Method
This appliance
must be permanently
grounded
in accor-
dance with the National
Electrical
Code and local codes and
ordinances.
1. Remove the terminal
access cover. (See Figures
11 and
12).
2. Install a strain relief into the opening
of the wire junction
box. (Figure 13, pg. 5).
3. Connect
the white and black wires of the power supply
cable to the white and black wire leads inside the terminal
access box.
4. Connect
the green ground
wire from the power supply
cable to the end of the green ground wire provided
in termi-
nal access box.
5. Replace the terminal
access cover.
6. Replace
front
panel
after
microwave
is installed
and
leveled using leveling
bolts as shown in Figure 14.
-ALTERNATE
GROUNDING-
If the
recommended
grounding
method
is impossible,
permanently
ground
the appliance
from
the
green ground
wire (located
it-i the terminal
access box) to a grounded
cold
water
pipe'
using
a separate,
green
colored,
insulated
copper
conductor
of appropriate
size (no.16 minimum).
*Cold water pipe must have metal continuity
to electrical
ground
and not be interrupted
by plastic,
rubber
or other
electrically
insulating
connectors
(including
water meter or
pump) without
adding a jumper wire to these connections.
CAUTION:
(a) DO NOT GROUND
TO GAS SUPPLY PIPE.
(b) DO NOT CONNECT
TO ELECTRICAL
SUPPLY UNTIL
APPLIANCE
IS PERMANENTLY
GROUNDED.