Whirlpool UXT4030AYS0 Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan - Halaman 7

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan untuk Kap Ventilasi Whirlpool UXT4030AYS0. Whirlpool UXT4030AYS0 24 halaman. 30" (76.2 cm) and 36" (91.4 cm) range hood installation instructions

Whirlpool UXT4030AYS0 Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan
1=
Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
A
Power Supply Cable Installation
1. For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards
and local codes and ordinances. There must be enough
wiring from the fused disconnect
(or circuit breaker) box to
make the connection in the hood electrical terminal box.
For optional power supply cord kit installations, follow the
instructions
in the "Make Electrical Connections"
section.
2=
3=
A. Keyhole slot
Use 1/8"(3 mm) drill bit and drill 4 pilot holes as shown.
A
A. Drill pilot hole
Install the 4 - 4.5 mm x 13 mm mounting screws in pilot
holes. Leave about 1/4"(6.4 cm) space between screw heads
and cabinet to slide range hood into place.
2=
NOTE: Do not reconnect power until the installation is
complete.
Remove the screw from the terminal box cover. Remove
terminal box cover and set aside.
\\\\\\\\\\
1/4"
(6.4 ram)
Non-vent (recirculating) installations - Do not remove any
knockouts.
4. Remove metal grease filters. See the "Range Hood Care"
section.
3=
A. Terminal box cover
B. Screw
Remove the power supply knockout from the top or rear of
the vent hood (depending on the incoming location of your
home power supply cable) and install a UL listed or CSA
approved 1/2"strain relief.
A
A. Power supply knockout
4. Using 2 or more people, lift the hood into final position. Feed
enough electrical wire through the 1/2" UL listed or CSA
approved strain relief to make connections
in the terminal
box. Tighten the strain relief screws.
5. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the screws are in
the narrow neck of slots.