To wire through rear wall:
Mark a line 71/2"(19.0 cm) from the right of the centerline on
the wall. Mark the point on this line that is %" (1.9 cm) from
underside of cabinet. Drill a 11¼ '' (3.0 cm) diameter hole
through wall at this point.
i
_" (1.9 cm)
17W'
[_
i (19cm)
i
i
i
Centerline
Style 2 - Cut Openings for 7" (17.8 cm) Round Vent
System
Roof Venting
To make a 71/4"(18.4 cm) circle on the underside of the cabinet
top and bottom:
1. Mark a centerline on the underside of the cabinet bottom.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 71A'' (18.4 cm) circle
template.
4. Use saber or keyhole saw to cut a 71/4 '' (18.4 cm) diameter
opening.
5. Repeat steps 1-4 for the underside of the top of the cabinet.
Style 1 - Cut Openings for 31/4'' x 10" (8.3 cm x 25.4 cm)
Rectangular
Vent System
Roof Venting
To make a 4" x 101/2 '' (10.2 cm x 26.7 cm) rectangular
cutout
on the underside of cabinet top and bottom:
1. Mark lines 11/2"(3.8 cm) and 51/2"(14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼"(13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cuto
I'
"11/2"
(3.8
cm)
(14 cm)
5V4"
'_'
(13.3 cm)
*From wall, not cabinet frame
Wall Venting
To make a 4" x 101/2 '' (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 657/8" (167.3 cm) and
623/8 '' (158.4 cm) or 1/8"(3.2 mm) and 33/8"(9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 51¼"(13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
/
Centedine
Cabinet
I/
l
I
I
i
I
3%"
i"_
51/4"
(9.2 cm)
i
(13.3 cm)
_71/4'' (18.4 cm) diam.
cabinet
cutouts
*From wall, not
cabinet frame
Style 3 - Cut Openings for 3%" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 7" (17.8 cm) Round Vent Transition
Roof Venting
To make a 4" x 101/2 '' (10.2 x 26.7 cm) rectangular
cutout on
the underside of cabinet bottom:
1. Mark lines 11/2"(3.8 cm) and 51/2"(14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼"(13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*IW'(3.8 cm)
'ii
(14 cm)
/
51/4"
'il_
(13.3 cm)
*From wall, not cabinet frame