Whirlpool WVU17UC0JS Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan - Halaman 11

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan untuk Kap Ventilasi Whirlpool WVU17UC0JS. Whirlpool WVU17UC0JS 24 halaman. 30" 76.2 cm
Juga untuk Whirlpool WVU17UC0JS: Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan (24 halaman)

Whirlpool WVU17UC0JS Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan
3. For vented installations: Grease filters should be cleaned
using warm water, dishwashing liquid, and a non abrasive
brush.
For non-vented (recirculating) installations: The charcoal
filter is not washable. For information on ordering, see the
"Assistance or Service" section.
NOTE: To reduce the risk of fire or shock when the hood
is used in recirculation mode, use only the conversion kit
models listed below:
Recirculating kit: W11371717
To Replace the Filter:
1. To reinstall the filter, place the back edge of the filter into the
channel at the rear of the hood. Push the filter into place and
turn the filter retainer to secure the filter to the range hood.
2. Replace the screw in the grease filter retainer.
SEL0157858A

WIRING DIAGRAM

Light Switch
Off - On
BK
WH
LED BULB
E26
Motor characterstics
Power Supply
120 VAC
60 Hz
Frequency
Current
1.2±10%A
Power absorption
73±10% W
Motor resistance (ohms)
White - Red
17.1±10% Ohms
White - Black
13.6±10% Ohms
For supply connection
use wires suitable for
at least 75° (167°F)
Replacing the LED Light Bulb
Turn off the range hood and allow the light bulb to cool.
1. Disconnect power.
2. Remove the grease filters from the hood.
3. Remove the fused light bulb from behind the lamp spacer.
4. Screw a 120 V, 9 W maximum, LED light bulb with E26 base
into the socket.
5. Replace the grease filters.
6. Reconnect power.
If the new light does not operate, make sure the light bulb is
inserted correctly before calling service.
Motor Switch
Low - Off - High
BK
C25
N
For ADA compliance add these elements
Ground
Screw
L
G
Remote Switch
BK
BK
L
during the installation
11