Firesense LIP-10A-TGG-NTS-1 Manual - Halaman 11

Jelajahi secara online atau unduh pdf Manual untuk Pemanas Teras Firesense LIP-10A-TGG-NTS-1. Firesense LIP-10A-TGG-NTS-1 17 halaman. Outdoor patio heater

A minimum supply pressure of 7" W.C. is required for the purpose of input adjustment of natural gas. Storage of
an appliance indoors is permissible only if the source is disconnected and removed from the appliance. A gas
source must be stored outdoors in a well-ventilated area out of the reach of children. A disconnected gas source
must have dust caps tightly installed and must not be stored in a building, garage, or any other enclosed area.
The minimum permissible gas supply pressure of 7" W.C. is required for purpose of hose adjustment. The
minimum hourly of 15,000 BTU is required input rating for a heater for automatic operation rating less than full
input rating.
The pressure regulator and hose assembly used with the appliance must be in accordance with your gas source
supplier.
Natural gas source may be hazardous and should be checked by your gas supplier. Never use natural gas source
with a damaged valve connection.
The natural gas source must be constructed and marked in accordance with the specifications for gas source
supplier of the U.S. Department of Transportation (DOT) or the standard for cylinders, spheres and tubes for
transportation of dangerous goods and commission, CAN/CSA-B339.
Do not store a natural gas source under or near this appliance.
Place the dust cap on the gas source valve outlet whenever the
source is not in use. Only install the type of dust cap on the
natural gas valve. Other types of caps or plugs may result in
leakage of propane.
Leak Test
1. Make 2-3 oz. of leak test solution (one part liquid dishwashing detergent and three parts water).
2. Apply several drops of solution where hose attaches to natural gas source regulator.
3. Apply several drops of solution where regulator connects to natural gas source pipe.
4. Make sure all patio heater valves are OFF.
5. Turn cylinder valve ON.
IF BUBBLES APPEAR AT ANY CONNECTION, THERE IS A LEAK.
1. Turn natural gas valve OFF.
2. If leak is detected at hose/regulator connection, tighten connection and perform another leak test. If bubbles continue to
call our customer service hotline at 1-866-985-7877, 9 a.m. – 6 p.m., EST, Monday – Friday.
appear,
ASSEMBLY

OPERATING INSTRUCTIONS

11