CALECTRO CALAIR-PR-230V Instruksi Instalasi - Halaman 4

Jelajahi secara online atau unduh pdf Instruksi Instalasi untuk Pengontrol CALECTRO CALAIR-PR-230V. CALECTRO CALAIR-PR-230V 12 halaman.

CALECTRO CALAIR-PR-230V Instruksi Instalasi
13
Output range high
14
Operation mode
15
Mean operation mode
16
Temp. sensor type
17
Temp. compensation low
18
Temp. compensation high
19
Temp. compensation
20
Temp. sensor adjust (°C)
21
High pressure alarm trig.
22
Low pressure alarm trig.
23
High pressure alarm enable
24
Low pressure alarm enable
25
Alarm delay
26
DI1 setpoint
27
DI2 setpoint
28
DI1 function
29
DI2 function
30
Override DAC from MODBUS
31
Override DAC value
32
Override relay from MODBUS
33
Override relay value
34
Calibration value
35-44
FIFO Alarm log
(*1) Value is multiplied with 10.
(*2) Operation mode
1.
Regulator mode
2. Pressure sensor -50Pa to +50Pa
3. Pressure sensor 0Pa to 100Pa
4.
Pressure sensor 0Pa to 150Pa
5. Pressure sensor 0Pa to 300Pa
6. Pressure sensor 0Pa to 500Pa
7.
Pressure sensor 0Pa to 1000Pa
8. Pressure sensor 0Pa to 1600Pa
9.
Pressure sensor 0Pa to 2000Pa
(*3) Mean operation mode
1.
Regulation on direct pressure value
2. 1.28 sec. mean value
3. 2.56 sec. mean value
(*4) Temperature sensor type
1.
CALAIR-PR-NTC
2. Pt1000
3. Temperature from MODBUS
4.
NONE/OFF
(*5) Digital input operation
1.
Motor alarm function
2. Force setpoint (DI1/DI2 setpoint)
(*6) Register 30 (Override DAC from MODBUS)
must be set to '1'
(*7) FIFO Alarm log (latest alarm on register 44)
0. No alarm
1.
High pressure alarm
2. Low pressure alarm
3. DI1 motor alarm
4.
DI2 motor alarm
5. Temperature sensor error alarm
4
0-100%
1-9(*2)
1-3(*3)
1-4(*4)
-20° to +30°
-20° to +30°
0Pa to 500Pa
-30 to +30(*1)
0Pa to 2000Pa
-50Pa to 2000Pa
1,2(*8)
1,2(*8)
0-10min
0Pa to 2000Pa
0Pa to 2000Pa
1-2(*5)
1-2(*5)
0,1
0-10V(*1,6)
0,1
0,1(*9)
-100Pa to 2000PA
0-9(*7)
(*8) Alarm enable
1.
Enable
2. Disable
(*9) Register 32 (Override relay from MODBUS)
must be set to '1'
Reservation för förändringar och tryckfel.
ENGLISH
Pressure regulator 230V with Modbus RTU
communication, alarm relay and digital inputs.
WARNING: IMPORTANT
!
INFORMATION ON
ELECTRICAL SAFETY AND
THE ENVIRONMENT
This product contains life-threatening voltages.
Disconnect the power supply before opening
the enclosure.
Power is to be supplied to the product via a
nearby mains switch which is marked: "Mains
switch for CALAIR-PR-230V pressure regula-
tor". The product's relay contacts can be sup-
plied with 230V and must be disconnected
when maintenance work is carried out. The
product is designed for indoor use. The prod-
uct is not to be exposed to fluids or moisture.
The outside of the product can be cleaned
with a lightly moistened cloth. The product is
designed to be installed in spaces that the gen-
eral public do not have access to. The product
is fitted with load anchored cable lead-throughs
which must be tightened on installation. Check
that the cable anchor functions correctly on
installation and adjust where necessary.
LANGUAGE SELECTION
RW
Simultaneously press both ▲ and ▼ to enter the
RW
language selection menu. Select language and
confirm by pressing Enter
RW
RW
TECHNICAL DATA
RW
Supply voltage:
RW
Power consumption:
Output signal:
RW
RW
Built in glass fuse
5x20 mm:
RW
fuse
RW
Alarm relay:
RW
Modbus
communication:
RW
RW
- Parity selectable:
- Speed (baud rate, kbps): 9.6 / 19.2 / 38.4 /
RW
RW
- Address:
Digital inputs:
RW
Pressure range:
RW
Display:
RW
Outdoor temp. sensor: Pt1000 and NTC (as
RW
RW
Ambient temperature: -30 to +50°C
RW
Cable entries:
R
- 'knockouts':
R
Screw terminal block
cable dimension:
Dimensions (WxHxD): 109x195x52 mm
Weight:
Protection:
FUNCTION
The
CALAIR-PR-230V
measures differential pressure and controls
ventilation system fans via a 0-10V signal.
Compensation of the setpoint for outdoor tem-
peratures requires the connection of an outdoor
temperature sensor to the CALAIR-PR-230V.
Two digital inputs can be used, for example for
monitoring a fan motor and activation of other
setpoints. CALAIR-PR-230V can be read and
be programmed via Modbus RTU (RS485). The
control rate is adjustable to allow adaption to dif-
ferent pressure control applications such as roof
fans. All settings/programming are saved in the
event of a power failure. CALAIR-PR-230V is fit-
ted with an alarm relay with potential-free chan-
ge-over contacts which can be programmed for
different alarm indications, such as high and low
pressure alarms. The ten last alarms are recor-
ded and saved in an alarm log.
Function is guaranteed with hose up to 100 m.
After installation, check that air can flow through
the hose.
MOUNTING
The CALAIR-PR-230V is installed vertically
with cable fittings and hose connections point-
ing downwards. There are notches in the base of
the CALAIR-PR-230V for 3 attachment screws,
which can be used to mount the unit. To remove
the cover, insert the end of a screwdriver into the
rectangular holes in the cover's snap fastener on
the upper edge of the enclosure. Carefully prise
out the snap fastener until the upper edge of the
cover opens. Draw the cover outwards until the
.
230V AC ±10%, 50 Hz
Max 6 W
0-10V, (minimum input
impedance 10 kΩ)
50 mA, delay action
Change-over 5 A, 250V
Modbus RTU via
RS485
None, even or odd
57.6 / 115.2
1-247
2 inputs
0-2000 Pa
OLED, yellow text on
black background
for previous CALAIR-PR)
1xM20 (cable 8-13 mm),
3xM12 (cable 3-6 mm)
1xM16, 1xM12
Supply voltage and
alarm relay max 2.5 mm
,
2
other connection
blocks max 1.5 mm
2
Ca 500 g
IP54
pressure
regulator