Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Sistem Pemanas AERA AZURE WHEEL. AERA AZURE WHEEL 17 halaman. Rotary heat recovery ventilation
- Make sure that equipment is firmly seated before lifting it.
Risk of injury! Watch out for nails when disassembling the timber frame!
Warning! Risk of personal injury and equipment damage!
Due to a high center of gravity, some equipment can tend to tip over and cause damage to persons and property.
- When transporting the unit, carefully observe its behavior and do not get near any possible hazardous areas.
1.6 Intended use
AZURE WHEEL 25 device is designed to correspond the need of 2500 m
fresh air side and a ePM10 50% class filter on the exhaust side as standard. The units are produced according to European Union
energy criteria.
AZURE WHEEL devices are designed with high energy efficient, low sound pressure and low power consumption plug fans. Plug
fans with EC motors can be driven with 3 fixed speeds or steplessly with the help of an air quality sensor thanks to build in smart
control system.
The AZURE WHEEL units are equipped with rotary heat exchangers. Through this procedure more than 80 % of the extract air
heat is transferred to the external air. The supply air is led by the duct system to the primary (supply air needing) areas. The used
air is extracted from the secondary areas (like e.g. social rooms, toilets, showers etc.). It flows back through the ducting to the
ventilation unit, transfers the heat and is discharged by the exhaust air duct to the atmosphere.
The heat recovery efficiency depends on several factors, which include, among other things, air humidity and the temperature
variation of outside air and exhaust air. The fan performance can be adjusted by the controller in scope of delivery. Various
sensors e.g. CO
or humidity sensors (accessory) are available on request, with which automatic fan control is possible.
2
Permissible operating air temperature and humidity is 0/40 °C and 95% RH for AZURE WHEEL units.
1.7 Performance data
Mechanical connections must be made correctly in order to obtain maximum efficiency from the device. The device's thermal
efficiency, sound level and electrical performance may vary depending on the ambient conditions the device is operating. These
conditions may affect the measurement result on site and vary from the catalogue data.
1.8 Guideline series VDI 6022
The AERA AZURE WHEEL ventilation units in this series are produced compliant with VDI 6022. The guidelines range from
operating regulations and material requirements through to construction regulations, which ensure high air quality. It must be
ensured that only original AERA accessories are used for operation compliant with VDI 6022.
1.9 Heat systems
The simultaneous use of controlled ventilation (AZURE WHEEL) and heat systems which depend on room air (tile oven, gas stove
etc.) requires compliance with all applicable regulations.
The use of heat systems which depend on room air are only permitted in state-of-the-art dense apartments with separate
combustion air supply; only then are AZURE WHEEL and heat systems decoupled from each other and operable meeting the
demands.
The relevant applicable regulations on the combined use of heat systems, domestic ventilation and extractor hoods (Federal
Association of Chimney Sweeps (ZIV)) must be observed!
3
/ h air flow. There is a ePM1 55% class filter on the
4