Caleffi solar iSolar 2 Manual - Halaman 8
Jelajahi secara online atau unduh pdf Manual untuk Pengontrol Caleffi solar iSolar 2. Caleffi solar iSolar 2 20 halaman.
2.2.3 System screen
system screen
collector 1
pumps
tank heat exchanger
2.3 Flashing codes
2.3.1 System screen codes
2.3.2 LED flashing codes
| 8
sensors
tank
collectors
with collector sensor
tank 1 and 2
with heat exchanger
The system screen (active arrangement) shows the scheme
which has been selected. The screen consists of several
system component symbols, which are - depending on the
current status of the system - either flashing, permanently
shown or „hidden".
tank top sensor
tank 2 or after-heating (with
additional symbol)
• Pump symbols are flashing during initialisation phase
• Sensor symbols are flashing if the corresponding sensor
display channel is selected.
• Sensor symbols are flashing in the case of a sensor fault.
• Burner symbol is flashing if the after-heating is active
green:
everything OK
red/green flashing:
initialisation phase
manual operation
red flashing:
sensor fault
(sensor symbol is flashing quickly)
additional symbol: opera-
tion of the burner
temperature sensor
pump
After-heating
with burner symbol