Xerox XES Synergix 8855 Panduan Pengguna - Halaman 40
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Printer Xerox XES Synergix 8855. Xerox XES Synergix 8855 44 halaman. Engineering printer
CARE
Cleaning the Lower Corotron
Periodic
cleaning
of
corotron
will
reduce
quality problems caused by
accumulation of toner inside
the printer.
CAUTION
Use care when removing and
replacing the corotron to avoid
scratching the photosensitive
drum inside the printer. Do not
force the corotron in or out of
the printer.
the
print
1. Switch off the power to the
printer.
2. Open the right side cover.
3. Locate instruction label (2)
and follow the instructions
to remove and replace the
lower corotron: (2).
5. Lay the corotron on a flat
surface to expose the
corotron wires for
cleaning.
6. Clean the corotron wires
using a lint-free cloth
dampened with water.
7. Rub the wires gently from
end to end until most of
the toner is removed.
8. Allow the corotron to dry
before replacing.