Direct power BP6L15 Panduan Keselamatan dan Pengoperasian - Halaman 12

Jelajahi secara online atau unduh pdf Panduan Keselamatan dan Pengoperasian untuk Kompresor Udara Direct power BP6L15. Direct power BP6L15 16 halaman. 6l compressor

few seconds and is quite normal. Check all valves
and regulators for leaks.
5.CONNECTING HOSES AND ACCESSORIES
Warning! Do not operate accessories at an air
pressure greater than the maximum rated air
pressure for the accessory.
Connect a hose to the compressor using the hose
to compressor quick release connector (See Fig.7).
With a hose and accessory fitted, determine the
working pressure of the accessory by referring to
the accessory manual. Slowly open the air outlet
pressure regulator (See Fig.8) at the same time
observing the air outlet pressure gauge until the
pressure gauge reads the minimum pressure for
the accessory. Fine adjustments to the air pressure
can be made until the accessory is working at its
optimum performance.
When the correct operating air pressure has been
set, the air outlet pressure regulator can be locked
by tightening the locking ring (See Fig.9). Do not
exceed the maximum rated air pressure for the
accessory.
To disconnect a hose push the hose connector
towards the compressor and at the same time pull
back the brass collar, this will allow the hose to be
removed (See Fig.10).
Fig 7
Fig 8
Fig 9
Fig 10