Step 3
WellTell-X Host Communication Wiring
NOTE: If the unit came preconfigured from the factory, ignore the
following wiring instructions.
Wiring of the WellTell-X host to a parent device (XFC/XRC) is fairly
simple. In the example (see Figure 6), an XFC-195 board is used as the
parent meter. If the application involves something other than the XFC-
195, please check the meter pinouts before proceeding.
Additionally, the following example uses COM 2 of the XFC. COM 1 is
often defaulted for communication with a remote device (radio, modem,
etc.). Wiring is simplified by the use of pre-wired cable that is designed
specifically for the WellTell-X device.
Figure 6 – Wireless Host Wired to COM 2 of XFC-195
Step 4
Configuring COM 2 for the LevelMaster Application
After completing the electrical wiring for the WellTell-X to COM 2 on the
flow computer, the user needs to configure the COM 2 communication
port.
NOTE: In Figure 6, COM 2 (XA2) must have an RS-485 module inserted.
Figure 7 walks the user through the steps (A and B) to configure COM 2
for the LevelMaster application.