eControls Comfort365 C365C32 Panduan Pemasang - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pemasang untuk Termostat eControls Comfort365 C365C32. eControls Comfort365 C365C32 8 halaman. Wiring hub, model wh11 and wh32
Juga untuk eControls Comfort365 C365C32: Panduan Pemasang (4 halaman)
!
The NEXT key is used to display the next option.
The ENTER key is used to save options and return to normal
!
thermostat operation.
The hidden BACK key is used to return to previous options
!
and is located to the left of the NEXT key.
10 Setting On-Off Temp Differential
Factory Default: #1. Range: 0, 1 or 2.
Touch the UP/DOWN keys to select 0,
1, 2.
Touch NEXT or ENTER.
o
Differential Mode0
0.5 On/Off Span.
o
Differential Mode1
1.0 On/Off Span.
o
Differential Mode2
1.5 On/Off Span.
11 Smart Recovery
Factory Default: Off. Range: On or Off.
Smart recovery initiates a heating or cooling call so that the space is at temperature
when the setback period ends.
Touch the UP key to select ON to turn
on smart recovery or touch the
DOWN key to select OF to turn smart
recovery off.
Touch NEXT or ENTER.
12 Vacant Heating Setpoint
o
Factory Default: 65 F.
Range: 44 F to 75 F
Touch the UP/DOWN keys to select
the heating temperature when the
space is vacant.
Touch NEXT or ENTER.
13 Vacant Cooling Setpoint
o
Factory Default: 80 F.
Range: 74 F to 95 F
Touch the
UP/DOWN
keys to
select the cooling temperature
when the space is vacant.
Touch
NEXT
or
ENTER.
14 Calibrate Downstairs Temperature Sensor
Factory Default: None.
Range - +/-5
Touch the UP/DOWN keys to change
the downstairs (Inside) temperature to
the temperature that the user feels is
correct.
Touch NEXT or ENTER.
Option
NEXT
ENTER
Option
NEXT
ENTER
o
o
Option
Heat
Vacant
NEXT
ENTER
o
o
Option
Cool
Vacant
NEXT
ENTER
o
Option
Inside
NEXT
ENTER
15 Calibrate Upstairs Temperature Sensor
Factory Default: None.
Range - +/-5
Touch the UP/DOWN keys to
change the upstairs (Inside2)
temperature to the temperature
that the user feels is correct.
Touch NEXT or ENTER
16 Airflow Update Time
Factory Default: 2 Minutes. Range: 1 to 20 Minutes.
This is the frequency, in minutes, that the damper position is updated.
Touch the
UP/DOWN
keys to
set the time in minutes to
update the upstairs and
downstairs airflow.
Touch
NEXT
or
ENTER.
17 Night Level LCD Backlight
Factory Default: On. Range: On or Off.
The LCD has a low level backlight that can be used as a night light.
Touch the
UP
key to turn the
low level backlight ON or touch
the
DOWN
key to turn OFF.
Touch
NEXT
or
ENTER.
18 Airflow Control, On or Off
Factory Default: On. Range: On or Off.
This option turns the automatic airflow control on or off. If on, the
thermostat will automatically adjust the airflow. If off, airflow is disabled.
Touch the
UP
key to select ON
for airflow control or touch the
DOWN
key to select OFF to
disable airflow control.
Touch
NEXT
or
ENTER
.
19 Upstaging Time
Factory Default: 5 minutes. Range: 0 to 30 minutes
Touch the
UP/DOWN
keys to
set the time at which second
stage heating or cooling is
activated.
Touch
NEXT
or
ENTER.
6
o
Option
Inside2
NEXT
ENTER
Option
NEXT
ENTER
Option
Night
NEXT
ENTER
Upstairs
Option
Airflow %
Downstairs
NEXT
ENTER
Option
NEXT
ENTER