eControls Comfort365 C365T11 Panduan Pengguna - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Termostat eControls Comfort365 C365T11. eControls Comfort365 C365T11 4 halaman.
Juga untuk eControls Comfort365 C365T11: Panduan Pengguna (4 halaman), Penginstal dan Panduan Pengguna (13 halaman), Penginstal dan Panduan Pengguna (13 halaman), Penginstal dan Panduan Pengguna (13 halaman), Penginstal dan Panduan Pengguna (13 halaman), Instalasi (2 halaman)

eControls Comfort365 C365T11 Panduan Pengguna
Temperature Override
If the thermostat is in SCHEDULE MODE, the setpoint temperature can
be overridden using the UP/DOWN keys. The setpoint temperature will be
held for 3 hours. After 3 hours the thermostat returns to normal operation.
Upstairs
Airflow %
Cool
Set To
Auto
Schedule
Downstairs
Inside
Day
Tu
AM
MENU
MODE
Displaying the Upstairs Temperature
The thermostat displays the downstairs temperature and is indicated
by INSIDE. The upstairs temperature will be indicated by INSIDE2. In
Night Mode, the thermostat displays the upstairs temperature,
indicated by INSIDE2.
Upstairs
Airflow %
Cool
Set To
Auto
Schedule
Downstairs
Day
Inside2
We
AM
MENU
MODE
Overriding Automatic Airflow
In AUTOMATIC AIRFLOW MODE, the user can override the airflow to
the upstairs and downstairs by pressing AIRFLOW % in the area
shown and then use the UP/DOWN keys to adjust the airflow. After 3
hours, the thermostat returns to automatic operation. UPSTAIRS,
AIRFLOW% and DOWNSTAIRS blink when in airflow override.
Upstairs
Airflow %
Auto
Hold
Downstairs
Inside
Eve
We
SYSTEM
PM
MENU
MODE
This area will blink when
in airflow override.
Terminating Airflow Override
AIRFLOW OVERRIDE can terminated by pressing
area shown and then pressing the Mode key. The thermostat returns
to automatic airflow control. The AIRFLOW % returns to the airflow
prior to the override.
Upstairs
Airflow %
Hold
Downstairs
Inside
Eve
We
SYSTEM
PM
MENU
MODE
Touch the UP/DOWN keys to adjust the
setpoint temperature.
After 3 hours, the thermostat returns
COOL
to normal thermostat operation.
SYSTEM
AUTO
FAN
To display the upstairs temperature,
touch the INSIDE temperature as
indicated. The thermostat will now
display the upstairs temperature,
COOL
indicated by INSIDE2.
SYSTEM
After about 30 seconds, the
AUTO
thermostat will return to displaying
FAN
the downstairs temperature.
Touch AIRFLOW% as shown.
Touch the UP key to increase the
upstairs airflow (the downstairs airflow
will automatically decrease). Touch the
COOL
DOWN key to increase downstairs airflow
(the upstairs airflow will automatically
AUTO
decrease).
FAN
The override range is defined by the
installer during set up.
AIRFLOW %
Touch AIRFLOW% as shown.
Touch the MODE key to terminate airflow
override.
COOL
The thermostat returns to automatic
airflow control. The AIRFLOW % returns
AUTO
to the airflow prior to the override.
FAN

User Options

Set Schedule
Selecting Manual or Auto Airflow
Turning Nighttime Airflow Option On or Off
Setting Nighttime Airflow in Heating
Setting Nighttime Airflow in Cooling
Cleaning the Touchscreen
Factory Set Schedule
The thermostat comes pre-set with the following energy-saving
schedule for weekdays (Monday-Friday) and weekends
(Saturday-Sunday).Using these settings can reduce your
heating/cooling expenses.
Monday through Friday
Morn
Day
Even
Nite
Saturday and Sunday
Morn
Day
Even
Nite
Change Factory Set Schedule
Touch the
MENU
key to display SCHEDULE. Select either the weekday
or weekend schedule to display or change. If no key is touched, the
thermostat returns to normal operation after about 30 seconds.
Schedule
Mo
Tu
We
ThFr
MENU
NEXT
Schedule
Morn
Mo
Tu
We
ThFr
AM
MENU
NEXT
in the
Schedule
Morn
Mo
Tu
We
ThFr
AM
MENU
NEXT
Schedule
Morn
Mo
Tu
We
ThFr
AM
MENU
NEXT
Continue setting the start times, heating setpoints, cooling setpoints for
the Day, Evening and Night schedules.
Touch ENTER to save the schedules to the weekdays or the weekend.
Time
Heat
6:00 AM
70
8:00 AM
62
6:00 PM
70
10:00 PM
62
Time
Heat
6:00 AM
70
8:00 AM
62
6:00 PM
70
10:00 PM
62
SELECTING THE WEEKDAY OR
WEEKEND SCHEDULE
Touch the UP key to select the weekday
schedule (MoTuWeThFr) or touch the
DOWN key to select the weekend
schedule (SaSu) and then touch NEXT.
ENTER
SETTING THE MORNING SCHEDULE
START TIME.
Touch the UP/DOWN keys to change the
Morning Schedule Start Time and then
touch NEXT.
ENTER
SETTING THE MORNING SCHEDULE
HEATING TEMPERATURE.
Heat
Set To
Touch the UP/DOWN keys to change the
Morning Schedule Heating Setpoint and
then touch NEXT.
ENTER
SETTING THE MORNING SCHEDULE
COOLING TEMPERATURE.
Cool
Set To
Touch the UP/DOWN keys to change
Morning Schedule Cooling Setpoint and
then touch NEXT.
ENTER
Cool
75
83
75
78
Cool
75
83
75
78