(3-4) SYSTEM REAL TIME MESSAGES
(3-4-1) ACTIVE SENSING
STATUS
11111110 (FEH)
Transmitted at every 200 msec.
Once this code is received, the instrument starts sensing.
When no status nor data is received for over approximately 350 ms, MIDI receiving buffer will be cleared, and the
sounds currently played is forcibly turned off.
Also, the values of the Controllers are reset to the default settings.
(3-5) SYSTEM EXCLUSIVE MESSAGE
(3-5-1) UNIVERSAL NON REALTIME MESSAGE
(3-5-1-1) IDENTITY REQUEST (Receive only)
F0H 7EH 0nH 06H 01H F7H
("n" = Device No. However, this instrument receives under "omni.")
(3-5-1-2) IDENTITY REPLY (Transmit only)
F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH 00H 00H 00H 7FH F7H
dd: Device Number Code
CP5: 3FH, 06H
CP50: 40H, 06H
(3-5-2) PARAMETER CHANGE
(3-5-2-1) NATIVE PARAMETER CHANGE, MODE CHANGE
11110000
F0
01000011
43
0001nnnn
1n
0*******
**
0*******
**
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0ddddddd
ddddddd
|
|
11110111
F7
For parameters with data size of 2 or more, the appropriate number of data bytes will be transmitted.
See the following MIDI Data Table for Address.
(3-5-3) BULK DUMP
11110000
F0
01000011
43
0000nnnn
0n
0*******
**
0*******
**
0bbbbbbb
bbbbbbb
0bbbbbbb
bbbbbbb
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0
0
|
|
0ccccccc
ccccccc
11110111
F7
See the following MIDI Data Table for Address and Byte Count.
The Check sum is the value that results in a value of 0 for the lower 7 bits when the Byte Count, Start Address, Data
and Check sum itself are added.
(3-5-4) DUMP REQUEST
11110000
F0
01000011
43
0010nnnn
2n
0*******
**
0*******
**
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
11110111
F7
See the following MIDI Data Table for Address and Byte Count.
(3-5-5) PARAMETER REQUEST
11110000
F0
01000011
43
0011nnnn
3n
0*******
**
0*******
**
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
0aaaaaaa
aaaaaaa
11110111
F7
See the following MIDI Data Table for Address.
Exclusive status
YAMAHA ID
device Number
Model ID
CP5: 7F, CP50: 7F
Model ID
CP5: 10, CP50: 11
Address High
Address Mid
Address Low
Data
End of Exclusive
Exclusive status
YAMAHA ID
device Number
Model ID
CP5: 7F, CP50: 7F
Model ID
CP5: 10, CP50: 11
Byte Count
Byte Count
Address High
Address Mid
Address Low
Data
Check-sum
End of Exclusive
Exclusive status
YAMAHA ID
device Number
Model ID
CP5: 7F, CP50: 7F
Model ID
CP5: 10, CP50: 11
Address High
Address Mid
Address Low
End of Exclusive
Exclusive status
YAMAHA ID
device Number
Model ID
CP5: 7F, CP50: 7F
Model ID
CP5: 10, CP50: 11
Address High
Address Mid
Address Low
End of Exclusive
(4) SYSTEM OVERVIEW (Keyboard, Sequencer and Tone Generator)
USB/MIDI = MIDI
SEQ
KBD
Local Switch
Tone Generator
USB/MIDI = USB
SEQ
KBD
Local Switch
Tone Generator
Although three types of note on/note off data, received via MIDI, played by the internal
sequencer and played on the keyboard will be distinguished, the other controllers (channel
messages) equally affect the entire notes.
ALL SOUND OFF clears all the sounds in the specific channel(s) played by both the
keyboard and the data via MIDI.
ALL NOTES OFF received via MIDI clears the sounds in the specific channel(s) played via
MIDI.
MIDI Data Format
To USB
From USB
MIDI Out
MIDI In
To USB
From USB
MIDI Out
MIDI In
33
CP5 / CP50 Data List