CALI neonLEDs NLED Panduan Petunjuk Instalasi - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Peralatan Pencahayaan CALI neonLEDs NLED. CALI neonLEDs NLED 12 halaman. Neonleds series

neonLEDs
Installation Instructions
TROUBLESHOOT
• Do not reset breaker or GFCI multiple times.
• If the unit is overloaded the breaker will trip shutting off the lights.
• If the breaker or GFCI reset button has been held down by hand or
any type of pressure (example: duct tape), or if the breaker has been
reset multiple times without trouble shooting, the unit will:
- Burn the primary or secondary wires due to high amperage caused
by overload and/ or short circuit in line which will not allow the
breaker to reset
- Damage the lighting
1.
Turn off power before beginning. Check for any twisting or damage to
the circuit in the LED lightstrip. If there is excessive damage and
circuit is broken, the lightstrip must be replaced.
Torn lightstrip
2.
Check for metal particles or other foreign objects causing the short.
Metal flakes
Metal flakes
Brown
Brown
3.
Check if cut is clean and not frayed, causing positive and negative
(Hot)
(Hot)
copper nodes to touch.
Frayed end
Green
(Ground)
Damaged lightstrip
Twisted lightstrip
Foreign object
Foreign object
CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
[email protected] \ calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
4.
Ensure the run is not too long and overlapping.
Excess lightstrip overlapping and
held down with tape or other force
5.
Ensure copper nodes are not making contact with aluminum extrusion.
Copper nodes touching extrusion
6.
Check for water inside end cap or power connector. Water needs to be
removed before connecting to power.
Water inside power connector
Water inside power connector
Water inside end cap
Water inside end cap
Black (-)
Black (-)
7.
24VDC
After above steps have been checked, replace 5A fuse, then follow
Red (+)
Red (+)
steps 5 - 7 on page 7.
White (-)
White (-)
Optional Dimmer
Blue (+)
Blue (+)
(not included)
Black (-)
NLED-120V
Troubleshooting (120V)
Compromised seal
Compromised seal
Compromised seal
Compromised seal
24VDC
Remove screw at end of
power plug to replace fuse.
Optional Dimmer
(not included)
10 of 10