TEST PROGRAM
Caution:
The Test No.065 "Factory Reset" will delete all setup data (included the data that the customer has purchased). Be sure to save
the important data to a computer via Musicsoft Downloader software, or tell this to the customer in advance.
1.
Measurement conditions
1-1.
Environment
Perform testing under following conditions.
▪ Ordinary temperature (5 to 40°C)
▪ Ordinary humidity (20 to 90 %)
If the test results deviate from the test standard range, however, re-test under such conditions as the ordinary temperature (5 to
40°C) and ordinary humidity (30 to 90 % of relative humidity).
1-2.
Power supply
Use an AC adaptor: PA-130, PA-130B or PA-130U
1-3.
Measuring instruments
▪ Frequency counter (capable of measuring to three or
more decimal places)
▪ Level meter
▪ Oscilloscope
* Use instruments with an input impedance of 1 MΩ or more.
1-4.
Test jigs
▪ Foot switch (FC-4A or FC5)
▪ Oscillator
▪ Stereo mini-plug cable
1-5.
Jack connection state
▪ [PHONES/OUTPUT] jack: Install a measuring instrument (L, R ch: 33 Ω load)
▪ [SUSTAIN] jack: Connect a Foot switch before turning the power ON
1-6.
Instrument settings
▪ MASTER VOLUME: MAX
▪ Other settings: the initial setup at turning the power ON.
(for pitch measurement)
(for output level measurement)
(for measuring popping noise)
(for inspecting [SUSTAIN] jack)
(for input of sinusoidal waveform to [AUX IN] jack)
(for inspecting [AUX IN] jack)
PSR-E373/YPT-370