1. Outward Drawing
Model No.
Suction A
Discharge B
C
736600
3.9
3.9
9.4
736605
5.5
5.5
11.1
736610
7.6
7.5
13.4
736675
10
10
14.2
736680
12
12
15.7
736685
12
12
15.7
2. Capacity
Model No.
736600
736605
736610
736675
Volt / Phase
120v / 60 Hz
120v / 60 Hz
120v / 60 Hz
120v / 60 Hz
Power Input:
90
124
164
W
Amphere: A
0.8
1.12
1.49
1.94
Revolution:
3300
3225
3225
3090
RPM (MAX)
Air Volume:
170
440
740
CFM (MAX)
Static Pressure:
2.01"
2.28"
2.30"
3.06"
Inch/Water(MAX)
Weight: Kg
2.8
3.0
9.0
3. Caution in Installation
If the unit is improperly installed, it may cause a breakdown or an accident. Do not
install in the following areas:
1) A place of frequent vibration or where vibration easily occurs. (Installation has to be a
sound place where there is no vibration.)
2) A place where the surrounding temperature exceeds 122°F or below 14°F.
3) A place where the temperature is freezing like a freezer.
4) A place where the is corrosive gas or use of chemical products.
5) A place where there is explosive dust or gas where it may occur.
6) A place where there is significant dust.
7) A place where there is significant humidity such as bathrooms, kitchens or other
rooms that have over 90% of humidity or where it may occur.
D
E
F
G
Make sure to disconnect the power in the e vent of a power outage. When power supply
is restored, the impeller may rotate rapidly causing an accident.
9.5
8.3
4.3
6.7
11.9
9.4
3.5
6.8
4. How to Install
13.8
12.0
3.5
8.3
1) When installing and carrying, be careful not to deform the impeller. If the wings are
14.7
8.7
6.3
8.66
deformed, it will be unbalanced and cause noise and vibration.
16.2
9.8
7.48
9.64
2) Use a filter on the absorption axis to prevent dust, oil and other foreign substances
on the impeller. (Filter selection may cause pressure loss for each type as well as the
16.2
9.8
7.48
9.64
wind volume may be lowered.)
3) For installation on the ceiling, make sure to install an inspection hole of at least
18" x 18" for repair and inspection.
736680
736685
120v / 60 Hz
240v / 120 Hz
230
300
310
2.54
1.3
3340
3340
780
1060
1060
Fan can be mounted to a floor, ceiling or wall. Attach fan to a sturdy surface like a stud
or other solid wood. Do not attach to a weak surface like sheetrock.
3.54"
3.54"
In all cases use the fixed mounting bracket and appropriate nuts and bolts to
8.0
9.5
9.5
attach the fan.
In using your fan, you should follow the IMPORTANT INSTRUCTIONS listed below. As
part of these instructions we have used the word WARNING which indicates a hazard
that, if not avoided, could result in death or injury.
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic safety precautions should always be followed to
reduce the risk of fire, electrical shock, and injury to persons, including the following:
Read all instructions before using this product.
• Use this fan only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electrical shock, or injury to persons.
• Extreme caution is necessary when the fan is used by or near children.
• Do not sit or stand on fan. Do not place objects on fan.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as
this may cause electric shock, and/or a fire hazard.
• A fan has arcing parts inside. Do not use it in areas where gasoline, paint or flammable
materials are used or stored.
• Do not operate any fan with a damaged cord or plug. Do not operate the fan, which
has been dropped, damaged or malfunctioned in any manner. Any repairs, or
electrical, or mechanical adjustments should be made by a qualified electrician.
• Do not insert hand or object into the rotation part (impellers).
• Make sure to disconnect power before touching, moving or servicing unit.
• Properly mount fan to a secure surface before operating.
• Do not overload your circuits. Check amp draw relative to amps available on the
circuit you want to connect the fan to.
• Do not allow any type of liquids to make contact with the fan.
• This product is intended for indoor use only.
• Use only with electrical wiring that is in good working order and meets applicable
codes.
5. Test Operation
• After completing installation, electric work, and duct work, perform the test operation
to check if it operates normally.
• After injecting the power, if wing is not rotating or rotation is slow, cut off the power
and check if the line connection is normally made.
• Check whether there is an abnormal sound or loss of wind during rotation.
6. Maintenance
• BEFORE CLEANING THE FAN DISCONNECT THE POWER CORD.
• Make periodic cleaning on filter absorption side & discharge head.