The fan uses a backward-inclined impeller
design that minimizes dust from collecting
on the blades. Each fan is statically and
dynamically balanced at the factory to
eliminate vibration and ensure quiet
operation. The entire motor and fan assembly
is mounted on a drop-down hinged access
panel for simple service and inspection,
and it can be removed from the fan without
disassembling the duct connections.
FAN CONTROLS
The fan can be operated manually or
automatically by a programmable timer,
dehumidistat, or other appropriate electronic
switch device. The fan may also be operated
in conjunction with a variable speed control.
LOCATING AND INSTALLING THE FAN
The compact dimensions and versatile
mounting options permit installation above
drop ceilings, between ceiling joists, or within
a small soffit location. The fan can be installed
horizontally or vertically.
Use ductwork of a diameter that is the same
as or greater than the diameter of the duct
connectors on the fan.
DUCTING THE FAN
The ducting from this fan to the outside of
the building has a strong effect on the air
flow, noise and energy use of the fan. Use the
shortest, straightest duct routing possible for
best performance, and avoid installing the
fan with smaller ducts than recommended.
Insulation around the ducts can reduce
energy loss and inhibit mold growth. Fans
installed with existing ducts may not achieve
their rated airflow.
ACCESSORIES
Accessories are available to accommodate
one or two bathrooms. Accessories are
included only when ordered as a Single-Port
Bath Fan Kit (SBFK).
PERFORMANCE
Fan airflow and energy performance are
tested in accordance with HVI procedures.
Reference RDF Installation
Supplement for additional
instructions and warranty
information.
© 2016 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of
American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA
941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
BACKDRAFT DAMPERS*
EXHAUST GRILLES*

MOUNTING BRACKET LOCATIONS

ELECTRICAL AND AIRFLOW PERFORMANCE*
Watts
Model
at 0.2"
0"
0.2"
Ps
VS4
21.3
101
VS4 MAX
38.1
138
122
VS6
40.1
220
178
VS6 MAX
63.3
287
261
*Certified airflow rating at 0.2" w.g. is derated from actual test results per HVI Certification procedure 920.
The HVI Certified Rate for VS4 = 80 CFM, VS4 MAX = 120 CFM, VS6 = 170 CFM, VS6 MAX = 260 CFM.
VS4: 115 V, 60 Hz, 21 W, 0.19 A, 2500 RPM
VS4 MAX: 115 V, 60 Hz, 34 W, 0.29 A, 3135 RPM
VS6: 115 V, 60 Hz, 41 W, 0.34 A, 2200 RPM
VS6 MAX: 115 V, 60 Hz, 59 W, 0.53 A, 2960 RPM
Above ratings are intended for sizing electrical wiring only.
NOTE: Performance shown does not reflect use of optional balancing devices.
VS SCHEMATIC
WALL HOOD
OR ROOF CAP*
CFM vs. Static Pressure
0.4"
0.6"
0.8"
1.0"
82
62
42
18
--
106
87
66
39
141
105
78
46
234
205
178 151
ELECTRICAL DATA
Actual consumption will be lower.
VS Series
FAN HOUSING
(Insulation may be installed
over the fan housing)
Duct joints, and ceiling
and wall penetrations
should be sealed
DUCTWORK*
*Sold separately
Refer to IOM text for details
ENERGY
STAR
1.2"
1.4"
1.6"
Certified
--
--
--
--
--
--
19
--
--
120
89
38
VS Series_IOM_0616
2