Zanussi ZRB324WO1 Panduan Pengguna - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kulkas Zanussi ZRB324WO1. Zanussi ZRB324WO1 30 halaman.

Zanussi ZRB324WO1 Panduan Pengguna

If something does not work

During operation of the appliance some smaller but
annoying trouble can often occur, which does not require
calling a technician out. In the following chart information is
given about them to avoid unnecessary charges on service.
We draw your attention that operation of appliance goes with
certain sounds (compressor- and circulating sound).
Problem
It is too warm in the
refrigerator
It is too warm in the
freezer
Water flows at the back
plate of the refrigerator
Water flows into the
chamber
Water flows onto the
floor
There are too much
frost and ice.
The compressor
operates continually.
The a ppliance does
not work at all.
Neither cooling, nor
lighting works.
Indicator lamps do not
give light.
The a ppliance is noisy.
In as much the advice does not lead to result, call the nearest brand- mark service.
Possible cause
Thermostatic control can be set wrongly.
If products are not cold enough or placed wrong.
The door does not close tightly or it is not shut
properly.
Thermostatic control can be set wrongly.
The door does not close tightly or it is not shut
properly.
Products in big quantity to be frozen were put in.
Products to be frozen are placed too closely to
each other.
It is normal. During automatic defrosting
frost melts on the back plate.
The outlet of the chamber can be clogged up.
Products placed in can prevent water from
flowing into the collector.
The melting water outlet flows not into the
evaporative tray above the compressor.
Products are not wrapped properly.
Doors are not shut properly or do not close tight.
The thermostatic control can be set wrongly.
The thermostatic control is set wrongly.
Doors are not shut properly or do not close tight.
Products in big quantity to be frozen were put in.
Too warm food was put in.
The appliance is in too warm place.
Plug is not connected to the mains socket
proper.
The fuse burnt out.
The thermostatic control is not on.
There is no voltage in the mains socket.
(Try to connect another appliance into it.)
The appliance is not supported properly.
This is not trouble, but means normal operation
We draw it to your attention again that the
appliance operates discontinuously, so the stopping
of compressor does not mean being no- current. That
is why you must not touch the electrical parts of the
appliance before breaking the circuit.
Set the thermostat knob to higher position.
Place the products to the appropriate place.
Check if the door closes well and the gasket is
unhurt and clean.
Set the thermostat knob to higher position.
Check if the door closes well and the gasket is
unhurt and clean.
Wait some hours and then check the
temperature again.
Place the products in a way so that cold air could
circulate among them.
Clean the outlet.
Replace the products so that they can not touch
the back plate directly.
Put the melting water outlet to the evaporative
tray.
Wrap the products better
Check if the doors close well and the gaskets are
unhurt and clean.
Set the thermostat knob to a position that gives
higher temperature.
Set the thermostat knob to a position that gives
higher temperature.
Check if the doors close well and the gaskets are
unhurt and clean.
Wait some hours and then check the temperature
again.
Put food at max. room temperature.
Try to reduce the temperature in the room where
the appliance stands.
Connect the mains plug properly.
Change the fuse.
Start the appliance according to instructions in
chapter "Putting it into use".
Call an electrician.
Check if the appliance stands stable (all the four
feet should be on the floor).
Solution
GB
9