Clarke 2090901 Petunjuk Pengoperasian & Pemeliharaan - Halaman 13
Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian & Pemeliharaan untuk Kompresor Udara Clarke 2090901. Clarke 2090901 20 halaman.
Unusual noise from
compressor.
Compressor
becomes too hot.
Bolts loose.
Flywheel loose.
Unit installed on an unsuitable
base.
Bearings, piston rings or cylinder
worn.
Valve broken.
Insufficient ventilation.
Oil level too low (check 2 or 3
times after stopping).
Fault in valves (machine not
stopping).
Blown head gasket (machine
not stopping).
Dirt on cooling fins or suction
filter.
Unit working at too high a
pressure.
Non-return valve partly
blocked.
Compressor being
overworked and running
continuously.
- 13 -
Tighten bolts.
Tighten flywheel.
Move unit to a more solid base.
Contact Clarke Service
Department
Contact Clarke Service
Department
See that sufficient air is supplied to
flywheel or fan of compressor and
that hot air is properly vented.
Fill with oil – see Page 10.
Contact Clarke Service
Department
Contact Clarke Service
Department
Clean cooling fins and suction
filter.
Contact Clarke Service
Department
Clean or that out non return
valve.
Connect to a supplementary
compressor or install a larger
model.