Zanussi ZEE6940 Panduan Pengguna - Halaman 12
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kompor Zanussi ZEE6940. Zanussi ZEE6940 36 halaman. Product manaul
Juga untuk Zanussi ZEE6940: Panduan Pengguna (16 halaman), Panduan Pengguna (48 halaman), Panduan Pengguna (40 halaman), Panduan Pengguna (12 halaman)
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on
the rating plate agree with the voltage and the power of
the local power supply.
• The appliance is fitted with a five pole terminal box
whose cables are predisposed for 230 V monophase
function.
1
2
3 4 5
In case of different voltage, carry out the connection as
shown in connection schematic table on the lower pro-
tection.
• Any electrical component must be installed or replaced
by the Service Force Centre technician or qualified
service personnel.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug af-
ter installation.
• Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
• The appliance must not be connected with an extension
cable, an adapter or a multiple connection (risk of fire).
Check that the ground connection is in conformity with
the standard and regulations force.
• The power cable must be placed in such a way that it
does not touch any hot part.
• Connect the appliance to the mains with a device that
lets to disconnect the appliance from the mains at all
poles with a contact opening width of minimum 3 mm,
eg. automatic line protecting cut-out, earth leakage
trips or fuse.
• None of a parts of the connection cable can not get a
temperature 90°C. The blue neutral cable must be con-
nected to the terminal block label with "N". The brown
(or black) phase cable (fitted in the terminal block con-
tact marked with "L") must always be connected to the
live phase.
12
Connection cable
Use only connection cable of type H05V2V2-F T90 or
equivalent type. Make sure that the cable section is appli-
cable to the voltage and the working temperature. The yel-
low/green earth wire must be approximately 2 cm longer
than the brown (or black) phase wire.
Building In
min. 450 mm
min. 55 mm
30 mm
10 mm
3 mm
A) supplied seal
B) supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to remove
and let an easy access in case a technical assistance inter-
vention is necessary.
min. 650 mm
550 mm
A
11 mm
11 mm
A
B
www.zanussi.com