• The appliance must not be connected with
an extension cable, an adapter or a multiple
socket. There is a risk of fire.
• Do not let the power cable to heat up to a
temperature of more than 90° C. The cable
should be guided by means of clamps fixed
to the side of the cabinet, in order to avoid
any contact with the equipment beneath the
cooktop.
• Make sure that there is access to the mains
plug after the installation.
Electrical Requirements
Permanent electrical installation must agree
with the latest I.E.E. Regulations and local Elec-
tricity Board regulations. For your own safety
the installation must be done by a qualified
electrician (e.g. your local Electricity Board, or a
contractor who is on the roll of the National In-
spection Council for Electrical Installation Con-
tracting [NICEIC]).
The manufacturer refuses to be held
responsible, if these safety measures
are not abided by.
Supply connections:
This hob has to be connected to 230 — 240 V
( 50 Hz) electricity supply.
The hob has a terminal block which is
marked as follows:
• L — Live terminal
• N — Neutral terminal
•
or E — Earth terminal
Before carrying out the connection, make sure:
1. The limiter valve and the electrical system
can take the appliance load (see the rating
plate)
2. The supply system is equipped with an effi-
cient earth connection in compliance with
the current standards and regulations
3. The outlet or omnipolar switch used for
connection is easily accessible with the
appliance installed.
The appliance is supplied with a 3 core flexible
powercable with a 3 amp plug. If it is necessary
to change the fuse, use a 3 amp ASTA-ap-
proved (BS 1362) fuse.
www.zanussi.com
A
E
A) Green and Yellow
B) 3 amp fuse
C) Brown
D) Cord clamp
E) Blue
The wires in the cord are coloured as follows:
Green and yellow
Blue
Brown
Replacement of the connection cable
1. Connect the green and yellow (earth) wire
to the terminal which is marked with the
letter 'E', or the earth symbol
oured green and yellow.
2. Connect the blue (neutral) wire to the ter-
minal which is marked with the letter 'N' or
coloured blue.
3. Connect the brown (live) wire to the termi-
nal which is marked with the letter 'L'. It
must always be connected to the network
phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
B
C
D
- Earth
- Neutral
- Live
, or col-
11