Zanussi ZGL 62 Buklet Instruksi - Halaman 13

Jelajahi secara online atau unduh pdf Buklet Instruksi untuk Kompor Zanussi ZGL 62. Zanussi ZGL 62 16 halaman. Zanussi instruction gas hob zgl 62
Juga untuk Zanussi ZGL 62: Buklet Instruksi (16 halaman)

Zanussi ZGL 62 Buklet Instruksi

Wiring Diagram

Fault Finding

Preliminary Electrical Systems Check
Brown
Blue
Blue
Green
Brown
Yellow
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
YES
NO
Carry out:
C: Polarity check.
Has inlet fuse blown?
NO
YES
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
A. TAPS IGNITOR SWITCHES
B. IGNITOR UNIT
PLUG (with cover removed)
Earth Wire
( )
Green/Yellow
Neutral Wire
Blue
Carry out:
D: Resistance to
Earth check.
A. EARTH CONTINUITY CHECK - Appliance must
be electrically disconnected - meter set on Ω (Ohms)
x 1 scale and adjust zero if necessary.
a) Test leads from any appliance earth point to earth
pin on plug. Resistance should be less than 0.1 Ω
(Ohm), check all earth wires for continuity and all
contacts are clean and tight.
B. INSULATION CHECK - Appliance electrically
disconnected, all switches ON.
a) meter set on Ω (Ohms) x 1 scale.
Test leads from L to N in appliance terminal block.
If meter reads «0» then there is a short circuit.
b) meter set on Ω (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads
less than ∞ (infinity) there is a fault.
NOTE - Should it be found that the fuse has failed but
no fault is indicated - a detailed continuity check (i.e.
by disconnecting and checking each component) is
required to trace the faulty component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should reveal
evidence of burning around the fault.
SOCKET
(face view)
( )
E
N
L
Electricity supply
should now be
satisfactory.
13