INSTALLATION INSTRUCTIONS

1
Attention!
• The new unit may only be installed and connec-
ted by an approved specialist.
• Repairs to the appliance are only to be carried out
by approved service engineers. Improper repairs
can cause significant hazards for the user. If your
appliance needs repairing, please contact our
customer service or your dealer.
Please follow these instructions, otherwise
3
the warranty is void in the event of damages.

Technical Data

Data
Appliance Dimensions
Width
Depth
Height outside
Height inside
Cut-Out Dimensions
Width
Depth
Corner radius

Regulations, Standards, Directives

This appliance meets the following standards:
• EN 60 335-1 and EN 60 335-2-6
in respect of the safety of electrical appliances for
household use and similar purposes and
• DIN 44546 / 44547 / 44548
in respect of properties of electric cookers for the
household.
• EN 55014-2 / VDE 0875 part 14-2
• EN 55014 / VDE 0875 part 14/12.93
• EN 61000-3-2 / VDE 0838 part 2
• EN 61000-3-3 / VDE 0838 part 3
in respect of basic electromagnetic compatibility
(EMC) requirements.
This appliance complies with the EU
Directives
• 73/23/EWG dated 19.02.1973 (Low Voltage
Directive)
• Flush-mounted units may only be operated follo-
wing installation in suitable installation cabinets
and workplaces which conform to the relevant
standards. This ensures sufficient protection
against contact for electrical units as required by
VDE.
• If your appliance malfunctions or if fractures,
cracks or splits appear:
– switch off all cooking zones,
– switch off the fuse for the cooking surface or
remove it.
Power Consumption
570 mm
Radiant heat single ring
500 mm
cooking zone ø 145 mm
54 mm
Radiant heat double ring cooking
51 mm
zone ø 180 mm - ø 120 mm
Induction cooking zone ø 145 mm
Induction cooking zone ø 210 mm
Induction cooking zone ø 210 mm
560 mm
490 mm
R3
Heating element voltage
Total Power, max.
• 89/336/EWG dated 03./05.1989 (EMC Directive
including Directive Amendment 92/31/EWG).
1200 W
1700 W/800 W
1400 W
2200 W
(P) 3000 W
230 V ~ 50Hz
6.5 kW