Clarke Air SP15ND Petunjuk Pengoperasian & Pemeliharaan - Halaman 7
Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian & Pemeliharaan untuk Kompresor Udara Clarke Air SP15ND. Clarke Air SP15ND 17 halaman. Engine driven
STARTING THE COMPRESSOR
1.
Open the drain cock and allow any condensate to drain compleatly,
•
The drain cock in located on the bottom of the receiver tank.
2.
Close the drain cock.
3.
Fully open the bleed valve.
4.
Connect the air hose to the air outlet. connect your air tool to the air hose.
•
Ensure the air outlet tap is closed.
5.
Start the engine, according to the instructions contained in the engine service
manual, if this is the first time you use the compressor, allow to run for 10 minutes.
6.
Close the bleed valve fully.
•
Pressure will build up in the receiver and eventually the air governor will
operate so that the engine runs off load.
•
The pressure registered on the pressure gauge should be 100psi.
7.
Use you air tool as indicated in its user guide
•
Observe the pressure gauge. When the pressure has dropped by approx.
20psi, the Air Governor/Load Genie will operate and the compressor will
cut in again.
STOPPING THE COMPRESSOR
1.
At the end of the day, stop the compressor in accordance with the
engine manual.
2.
Operate the air tool trigger or operating lever etc., to ensure there is no
pressure in the air line, then disconnect airline and tool.
DO NOT under any circumstances attempt to remove the air tool or disconnect
the air hose until you are satisfied that the pressure has been relieved.
3.
Finally, open the drain cock very slowly to release the pressure in the tank.
Take care not to touch the engine or pump as they remain hot for some time
after use.
Fig.2
WARNING!
- 7 -