• Before attaching the hood body, tighten the two
screws Vr
Vr Vr
Vr
Vr located on the hood body mounting
points.
• Hook the hood body onto the screws 12a
• Fully tighten support screws 12a
• Adjust screws Vr
Vr to level the hood body.
Vr
Vr Vr
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 9 9 9 9 on the hood body
outlet.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Remove any activated charcoal filters.
GB

Mounting the hood body

12a
12a
12a
12a
12a
12a
12a
12a
Connections

DUCTED VERSION AIR EXHAUST SYSTEM

17