Place the cooker checking that the loop
made by the flexible pipe develops in
the sanitary empty of the furniture.
Rigid pipe
•
Rigid pipe with screw nut
2. For cylinder butane propane gas:
•
We advise you to use flexible pipe
according to the national rule in force of
minimum 1 m; this length is chosen
depending on the position of the
connection to the gas supply;
•
For the old butane installations you can
use a flexible rubber pipe of max 1,5 m
and 6 mm diameter, mounted with the
special butane holder ;
•
Fix it well by means of a collar for each
end.
For buying the pipe
•
Flexible rubber hose: it has to be
marked NF GAS
•
Flexible pipe: according to standard NF
D 36 121, or NF D 103, or NF D 36 107
Fuse capacity: 16A
Note:
Check on the rating plate the value for the
total connection power for establishing the
fuse power.
In case of a direct connection to the mains
you have to interpose an omnipolar switch a
minimum opening between contacts of 3
mm.
The yellow-green grounding cable has not
to be interrupted by the switch.
The supply cord must be positioned in such
a way as it does not reach in any point a
temperature higher by 50ºC than the room
temperature.
Fitting
Holder
butane
Flexible
rubber
Necklace
Electrical connection
Important
In any connection way the appliance
has to be grounded, in accordance with
the national rules in force and with
standard NFC 15 100. We decline any
responsibility in case of accidents due to
no grounding or wrong grounding.
Before connecting check that:
•
fuse and household electric installation
can bear the charge of the appliance
(see rating plate);
•
The socket or the omnipolar switch used
for connection is easily reachable when
the appliance is installed.
How to proceed?
•
Unscrew and remove the protective
cover at the back of the appliance;
•
Connect the power cord to the terminal
of the cooker according to the table
no.1;
•
Fix by means of cable clamp;
•
Make sure that the connection to the
terminal is matching the network power;
•
Remount and screw the protective cover
at the back of the appliance.