ACOPOWER HY-S601 Manual Instruksi Universal - Halaman 9

Jelajahi secara online atau unduh pdf Manual Instruksi Universal untuk Generator Portabel ACOPOWER HY-S601. ACOPOWER HY-S601 10 halaman. 60000 mah/222w portable solar generator

Use fault analysis
1. Product indicator light is not bright after startup, and no output function ?
Reason: The product, with the software and hardware protection, when DC 12V
output overload or short circuit, will enter the hardware protection to can not
startup.
Solution: Use the original adapter to charge 5 seconds, it can be activated ! (If it
can not be activated, maybe the product has damaged, need to returned to the
manufacturer for repair.)
2. As AC output loading, the appliances can not work normally?
Reason: This product can only start loading the electrical appliances within 250W.
Please check the electrical load power, when it's higher than the rated load, the
product can't drive the load for overload protection.
Solution: Remove the load appliances, products can be use normally. Note that AC
output module of this product can only take carry the load under 250W electrical
appliances.
3. In high temperature environment, when the product is used, the AC load
suddenly stops working?
Reason: First, confirm the load within the 250W, the product high-temperature
load standard is 40 °C . In higher than this temperature, when the product is
overloading, it's easy to over temperature protection.
Solution: To lift the load, the product back to normal, Note that the product work
below 40 °C environment.
4. When charging, adapter heating?
Reason: The standard for the adapter, both inside and outside surface temperature
of the adapter, should be lower than 70 °C at room temperature environment. The
adapter temperature is a normal situation below 70 °C. If not, the adapter may be
abnormal.
Solution: Replace a new adapter with the same specifications.
5. As USB output loading, the appliances can not work normally?
Reason: This product can only load the appliances within 3.1 A. Please check the
electrical load power, when it's higher than the rated load, the product can't drive
the load for overload protection.
Solution: Remove the load appliances, products can be use normally. Note that
USB output module of this product can only take carry the load under 3.1A
electrical appliances.
6. When the product is charging and discharging, the built-in fan rotate
sometimes?
Reason: The product will get hot when charging and discharging, and design the
fan heatsink function to resist over temperature to improve the service life of
product. So the fan will start, which is a normal phenomenon.
10
【 IV 】LED light indicator instruction
Front
LED Condition
Part of LED lights on
Rolling
(from right to left)
All LED lights on
When the powerpack is switched on, the rear cooling fan will run for a second, AC
outlet will be turned on, and LED displays the current product remaining.
When charging, 5 LEDs will be on for a second, then starting rolling.
AC will stop when all 5 leds run off.
Current remaining
battery indicator
Charging
Full of charge
07