Clarke 7230582 Panduan Petunjuk Pengoperasian & Pemeliharaan - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian & Pemeliharaan untuk Pompa Air Clarke 7230582. Clarke 7230582 13 halaman. Submersible water pump
ELECTRICAL CONNECTIONS
nnect the mains lead to a suitable 110 Volt (50Hz) electrical supply through
Co
an approved plug or a suitably fused isolator switch, or to a suitable portable
110 volt transformer.
We recommend that this pump is fitted with a Residual Current Device (RCD).
If the pump is to be connected to an outdoor electrical supply, ensure both
the plug and the socket are of a British Standard approved waterproo
WARNING: THIS APPLIANCE MUST BE EARTHED
The wires in the mains lead are coloured according to with the following code:
Green & Yellow
As the colours of the flexible power cable of this appliance may not
correspond with the coloured markings identifying terminals in your plug
proceed as follows:
• Connect GREEN & YELLOW wire to the terminal marked with a letter "E" or
Earth symbol '
• Connect BROWN wire to terminal marked with a letter "L" or coloured RED
• Connect BLUE wire to terminal marked with "N" or coloured BLACK
IMPORTANT: If you are in any doubt regarding electrical installation, you should
consult a qualified electrician.
PUMP PERFORMANCE DATA
-
Earth
Blue
-
Neutral
Brown
-
Live
'or coloured GREEN or GREEN & YELLOW.
4
design.
f