PRIMING THE PUMP
Remove the filler plug on top of
the pump case and prime the
pump by filling completely with
water, leaving no air gap.
Remember the pump is self-
priming only when filled, after
which, it will re-prime itself without
refilling. Refilling is necessary only if
the pump has been drained, or if
all the water has been lost.
OPERATION
1. Open any valves in the pipeline.
2. Connect the power supply and switch the pump ON.
3. Wait for the pump to prime.
4. If the motor fails to start or the pump does not deliver water refer to
TROUBLESHOOTING.
NOTE: Filling the suction pipe with water will speed up the priming
process, and it is recommended that a non-return valve be fitted
to the end of the suction pipe.
In the event of blockages, where debris has entered the suction chamber, the
chamber can be taken off and cleaned out as described under
Maintenance.
5. Periodically, check the level of the water being removed and never allow
the pump to run dry.
6. Stop the pump by switching the pump the OFF (O) position.
ADDITIONAL CONSIDERATIONS
• Strain caused by vibration can be reduced by connecting a short
flexible hose between any rigid pipework and the pump.
• Any restriction in the pipeline will greatly reduce the flow.
• Ensure that the hoses and pipes are supported along their entire
length. They will be considerably heavier when filled with water.
• We recommend that you install isolation valves either side of the
pump in order to isolate the pump during maintenance/removal.