Medium-Pressure Material Pump
16. Shut off the control valve.
• Visually inspect the pump for external leaks.
• The pump should not cycle more than once or twice
in one hour.
If the pump does not stall, refer to the
Troubleshooting Chart for details.
17. Check the motor for air leakage.
If the motor leaks, refer to the Air Motor Service
Guide for details.
NOTE: The following procedures are appli-
cable for pumps with Teflon V-Packings.
18. Open the control valve and allow the pump to operate
for 5 minutes.
19. Inspect Packing Screw (12) for leakage.
Should oil (solution) overflow the torque hole in the
Packing Screw, tighten the Packing Screw clockwise an
additional 1/8 turn.
IMPORTANT: After 8-10 hours of operation,
inspect the Packing Screw for leakage once
again. Tighten an additional 1/8 turn as
required.
Alemite Corporation

Installation

Additional items that should be incorporated into the
air piping systems are listed in Table 5.
Part Number
338862
Moisture Separator/Regulator & Gauge Combination
5608-2
Moisture Separator
7608-B
Regulator and Gauge
5908-2
Lubricator *
Table 5 Air Line Components
* Although the air motor is lubricated at the factory,
the life of the motor can be extended with the use of a
lubricator.
15
SER 7896-A5
Description
Revision (2-04)