5.
Install the charging station on the selected
location with the rubber gaskets first and then
the washer and the four M8 screws.
CAUTION: Do not install the charging station without
the rubber gaskets. Otherwise it can leak in water
and cause damage to the EV charger.
6.
Make sure that the charging station is firmly
installed on the wall.
7.
Make sure to cover all open holes with silicon or
rubber gaskets to protect the charging station
against water.
6
To install the charging station on a
pole
•
For installation on a pole, refer to the manual
for the pole mount kit.
To do the cable installation
1.
Make sure that the power is off.
A 16 mm
2
A
2.
Make sure that the cable installation is
dimensioned (A) for the charging station.
CAUTION: The cable glands must be replaced if the
cables are outside this specified range.
User & installation instructions
+
3.
If the power cable and network cable should
be installed from below or from the back, drill
holes in the unit according to the illustration.
CAUTION: Make sure not to damage the
content inside the unit when you drill the holes.
4.
Install the cable glands in the holes to protect
the unit from dust and water penetration.
NOTE: The cable gland for the power cable that
is delivered with the product supports cable
dimensions between 11-17 mm and the gland for the
network cable supports cable dimensions 3-6 mm.
5.
If the power cable and network cable are
installed from the top, there are two holes on
the top of the unit. Install the power cable to
the larger hole (M25) and the network cable to
the smaller hole (M12).
To install the power cable
1.
Pull the power cable through the cable gland.
A
B
Min
500 mm
A
B
C
C
A
B
L1 L2 L3 N PE
A
B
C
L1 L2 L3 N PE
L1 L1 L2
L2 L3
L3 N N PE
PE
L1 L2 L3 N PE
18-20 mm
2.
Make sure that the protected ground wire is
longer than the other wires so that it will be the
last wire to detach if it is pulled.
3.
Strip the wires approximately 18-20 mm at the
end of the power cable. The cross-sectional
area of the power cable must not exceed 16
mm
. Follow the instructions on the previous
2
page.
4.
Connect the supply wires to the terminal
blocks.
NOTE: The terminal blocks are of push-in type. Make
sure that the cables are properly connected.
NOTE: For regional differences of the grounding
system, such as IT-Nett, refer to the supply input
schematic on page 13.