CTEK D250SA Panduan Pengguna - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Aksesori Mobil CTEK D250SA. CTEK D250SA 12 halaman. 2 x 40a
Juga untuk CTEK D250SA: Manual (13 halaman), Panduan Memulai Cepat (2 halaman)

CTEK D250SA Panduan Pengguna
Date: 2017-12-19
Version: 1.0
Starter battery:
Typically 55Ah to 100Ah for automotive applications.
A start battery should never be deeply discharged
Service battery:
Size 28Ah to 800Ah.
Batteries are connected in parallel to increase capacity
(Ah).
Suitable deep cycle batteries should be used.
Temperature sensor:
Attach the temperature sensor onto the service battery.
Title: SMARTPASS 120 with Charger at Starter battery
Fuses:
If fuses are used, mount the fuses as close to each
battery as possible.
Suitable fuse size:
D250SA: 30A
D250SA and SMARTPASS 120: 300A
Please verify directive for applicable installation
regarding fuses.
Wiring:
Please see instruction manual for suitable dimensions.
Please verify directive for applicable installation
regarding wiring.
A thick wire generate less voltage drop than a thinner
wire at high current.
Battery charger (AC):
When regular discharge on both Service and Starter
battery, a Battery charger required.
Connect the Battery charger on Starter battery and both
Starter and Service battery will be individually recharged
from the Battery charger and D250S DUAL/SMARTPASS.
Select a charger that is suitable regarding the capacity of
the battery bank and also the requirement of recharge
time. A typical charger is MXS25 or M300.
Consumers:
Critical consumers are connected directly to the service
battery bank. A critical consumer could be VHF radio.
Non critical consumers are connected directly to the
consumer output terminal at SMARTPASS 120. If battery
voltage reach a critical low level, the consumer output
terminal is deactivated to protect the Service battery.
Non critical consumers receive current from the
alternator instead of the Service battery during drivning,
to make the charing of the Service battery faster
SMARTPASS 120:
Install according to instruction manual.
Start assistance.
SMARTPASS 120 automatically connects the service
battery to the starter battery to
assist, if the starter battery on its own is unable to start
the engine. After the start assistance function
has been activated, SMARTPASS 120 will display a fault
indication until starting has been
achieved without using the start assistance function.