Clarke XR160 Panduan Petunjuk Pengoperasian & Pemeliharaan - Halaman 13

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian & Pemeliharaan untuk Pemanas Clarke XR160. Clarke XR160 17 halaman. Diesel/paraffin heaters
Juga untuk Clarke XR160: Panduan Petunjuk Pengoperasian & Pemeliharaan (17 halaman)

Clarke XR160 Panduan Petunjuk Pengoperasian & Pemeliharaan
TROUBLE SHOOTING
LED

OPERATION

Steady ON System Check System performing self test. No action required.
Steady OFF
2 Flashes
No flame
detected
3 Flashes
High limit
switch failure
(unit has over-
heated)
4 Flashes
Flame sensor
Failure
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLE SHOOTING
No action required.
Heater fails to start.
1. Check fuel level
2. Check the mains plug is correctly fitted and
that the fuse inside it has not blown.
3. Return to Clarke service department for repair.
Make sure heater is cooled down,
1. Make sure that the power switch is set to the
OFF position.
2. Wait 5 minutes
3. Start heater by setting the power switch to the
ON position.
Return to Clarke service department for repair.
13