Installation – Settings
DIP 5, 6 and 7: Timer function
The countdown starts when the cooker is turned on. When 5 minutes of
the set time are left, the Cooker Guard beeps once every 15 seconds for
5 minutes. Pressing the control button restarts the countdown.
DIP 5 DIP 6 DIP 7 Minutes (extended)
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
DIP 8: Autoconnect
NB: In order for this function to work, DIP 9 must be ON. Fifteen minutes
after turning the cooker off, the Cooker Guard will automatically be
reset and turn the power back on. On a cooker with rotary switches,
all the rings and oven must be turned off before the Cooker Guard will
reset itself automatically.
If this function is not activated or to reset the Cooker Guard manually,
press the control button on the sensor (or external switch panel,
optional extra).
DIP 8
OFF
ON
DIP 9: Current measurement
When current measurement is ON, the Cooker Guard will only give an
alarm when the cooker is in use. This includes all types of alarm signal,
including low battery.
NB: We recommend that you do not turn off current measurement,
as this will reduce battery life considerably.
DIP 9
OFF
ON
10
15 (2 h)
30 (2 h)
45 (2 h)
60 (2 h)
90 (2 h)
120 (12 h)
360 (12 h)
Off
Autoconnect
Autoconnect off
Current measurement
Current measurement off
Standard
Standard
Standard