Clarus 6400 Series Panduan Pemilik - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Unit Kontrol Clarus 6400 Series. Clarus 6400 Series 4 halaman. Automatic multizone valve
Problem
Valve does not change
or cycle to next zone
or outlet.
Water comes out of all
the valve outlets.
Valve skips outlets or
zones.
All Clarus Environmental products must be installed and maintained in accordance with all applicable codes.
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
3649 Cane Run Rd. • Louisville, KY 40211-1961 • (502) 778-2731 • FAX: (502) 774-3624
Troubleshooting and Service Checklist
Cause
Debris or foreign objects prevent-
ing proper movement of stem and
disk assembly.
Disk may have expanded and is
rubbing against inside walls of
body.
Restriction of flow causing pres-
sure in valve to build up, prevent-
ing valve from cycling.
Stem and disk assembly not seat-
ing properly on valve outlet.
This will case the valve to cycle
quickly several times, skipping one
or more zones.
Trusted. Tested. Tough.
clarusenvironmental.com
© Copyright 2019. All rights reserved.
•
Remove valve top and check for foreign
objects. Clean build-up from walls as
necessary.
•
Check for freedom of movement of stem and
disk assembly up and down over the center
pin in bottom of valve. Scale deposits may
build up on the pin and hold stem and disk
assembly down. Clean pin and again check for
freedom of movement.
•
Replace disk and clean build-up from walls of
valve as necessary.
•
Be sure that all operating outlets are not
capped and that the flow to operating zones is
not restricted in any manner.
•
The backflow of water from uphill lines may
be preventing the valve from cycling properly.
If the valve cannot be placed close to the high
point of the system, a check valve should be
installed near the valve in the outlet line that
runs uphill from the valve.
•
Check for sufficient water flow. A minimum of
15 GPM is required to properly seat the disk.
•
Remove the valve top and clean the inside
walls as necessary to ensure that nothing is
interfering with the up and down movement of
the stem and disk assembly inside the valve.
•
Make sure that the operating outlets are no
capped and that the flow to the operating
zones is not restricted in any manner.
•
Replace disk if necessary.
•
The stem and disk assembly is being advanced
past the desired outlet.
•
Ensure that the correct cam for the desired
number of zones is installed and that the out-
let lines are installed to the correct outlet ports
of the valve.
®
4
Solution