The OSHA Regulated Fusible Link that holds the lid open will release the lid if the
ambient temperature reaches 165 F. Never bend the Fusible Link, as it will weaken it.
WARNING! Do not coat or paint fusible link as this may prevent proper
operation. Inspect fusible link annually and replace if corrosion and/or stress is
evident.
J.

Leveling Bolts.

The front two legs contain bolts, which are used to minimize any rocking from uneven
floors, and will aid in leveling the unit. The unit must be level to work properly.
VII.

CARE AND MAINTENANCE

A.

Sump Maintenance.

From time to time the sump of the Parts Washer needs to be pumped clean. The interval
depends on usage. For motor pools this interval is 3-6 months. For weapons cleaning
this interval is 6 months to 1 year. To dump the sump, first remove the hose on the front
right side of the unit, remove the cap and put it either in a bucket or barrel and turn the
hose end valve on. Second, open the yellow valve handle on the main shelf. Third,
move the handle back and forth on the sump pump located on the shelf. Pump the sump
out till the solvent changes color. This usually takes 2-5 gallons. Turn off hose end
valve, yellow handle valve, replace cap and return it to its hangar. Dispose of waste
properly.
B.

Canister Lid O-Ring Maintenance

Every time the filters are changed, smear a small amount of petroleum jelly around the
o-ring to keep it lubricated.
WARNING! ALWAYS WEAR GLOVES AND EYE PROTECTION WHEN
HANDLING SOLVENT OR FILTERS.
WARNING! When changing filters, make sure to have something underneath the
used filter as you move it, such as a bucket or oilsorb, to capture any incidental
drips.
C.

Changing Filters.

The PCS-25/WCS-25/PCS-15 comes equipped with one or two 5" X 18" filter canisters.
Inside these canisters are 4.5" X 17" filter cartridges. These filters need to be changed
when indicated by the filter status lights or by a 40 PSI reading on the pressure gauge
mounted on the filter canisters. When the gauge or lights indicate a filter change is
needed please follow these steps:
1. Turn all power to the system off.
2. Unplug the unit from wall receptacle.
10