Lenovo ideapad 320L-17ISK Panduan Pemeliharaan Perangkat Keras - Halaman 26

Jelajahi secara online atau unduh pdf Panduan Pemeliharaan Perangkat Keras untuk Tablet Lenovo ideapad 320L-17ISK. Lenovo ideapad 320L-17ISK 46 halaman. Ideatab s2110a hardware maintenance manual v1.0
Juga untuk Lenovo ideapad 320L-17ISK: Panduan Pengguna (36 halaman)

Lenovo ideapad 320L-17ISK Panduan Pemeliharaan Perangkat Keras
Lenovo IdeaTab S2110A Hardware Maintenance Manual
Perform operational charging. If the battery status indicator or icon does not
light on, remove the battery pack and let it return to room temperature. Reinstall
the battery pack. If the charge indicator or icon is still off, replace the battery
pack.
If the charge indicator still does not light on, replace the system board. Then
reinstall the battery pack. If it is still not charged, go to the next section.

Checking the battery pack

Battery charging does not start until the Power Meter shows that less than 95%
of the total power remains; under this condition the battery pack can charge to
100% of its capacity. This protects the battery pack from being overcharged or
from having a shortened life.
To check your battery, move your cursor to the Power Meter icon in the icon tray
of the Windows
percentage of battery power remaining is displayed. To get detailed information
about the battery, double-click the Power Meter icon.
Note: If the battery pack becomes hot, it may not be able to be charged. Remove
it from the computer and leave it at room temperature for a while. After it cools
down, reinstall and recharge it.
To check the battery pack, follow the steps below:
1. Turn off the computer.
2. Remove the battery pack and measure the voltage between battery terminals
3. If the voltage is less than +11.0 V DC, the battery pack has been discharged.
4. If the voltage is more than +11.0 V DC, measure the resistance between
22
®
taskbar and wait for a moment (but do not click it), and the
1 (+) and 7 (-). See the following figure:
7(-)
6(-)
5
3 4
2(+)
1(+)
Note: Recharging will be continued for at least 3 hours, even though the
indicator does not light on.
If the voltage is still less than +11.0 V DC after recharging, replace the battery.
battery terminals 5 and 7. The resistance must be 4 to 30 KΩ.
If the resistance is not correct, replace the battery pack. If the resistance is
correct, replace the system board.
Terminal
Voltage (V DC)
1
+0 to +14
7
Ground (-)