AM Series Thermal Insulation Replacement Instruction
Replacing Burner's Thermal Insulation – Continued
3.
Remove the burner's thermal insulation (see Figure 12).
4.
Replace the O-Ring (see arrow in Figure 13) with the new one included in the kit.
Figure 12: Remove Thermal Insulation
5.
Install the wool gasket in the back of the new burner thermal insulation (see Figure
14).
6.
Install the new burner thermal insulation on the burner (see Figure 15).
Figure 14: Combine Wool Gasket with
Thermal Insulation
07/28/2014
AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288
Kit # 62632006
Figure 13: Replace the O-Ring
Figure 15: Install Thermal Insulation in Burner