7.0 product family specification
50 hz e. 2 series models
Hydraulic data
model
Nominal Hydr. Power (watts)
Max Flow (L/sec.)
Max Head (m)
Max. Efficiency (bep%)
Max. Fluid Temperature
Max. Ambient Temperature
Max. Working Pressure
Electrical (motor) data
model
Nominal input voltage
range @50 hz.
Full load current draw
@50 hz.(ac Amperes)
Speed @ max flow (rpm)
Max. Efficiency (bep%)
t o r o n t o
+1 416 755 2291
b u f f a l o
+1 716 693 8813
b i r m i n g h a m
+44 (0) 8444 145 145
m a n c h e s t e r
+44 (0) 8444 145 145
b a n g a l o r e
+91 (0) 80 4906 3555
s h a n g h a i
+86 (0) 21 5237 0909
a r m s t r o n g f lu i d t e c h n o lo g y
established 1934
s ã o p a u l o
+55 11 4785 1330
E.2 Series high efficiency
circulator
e7.2/
e9.2/
e7.2b
e9.2b
105
105
1.9
1.8
5.3
7.7
22.5
26.4
110°c (All models)
50°c (All models)
1034 kPa (All models)
e7.2/e7.2b
e9.2/e9.2b
220-240vac 220-240vac 220-240vac 220-240vac
0.80
0.90
2892
2855
22.5
26.4
e12.2/
e14.2/
e22.2/
e12.2b
e14.2b
e22.2b
252
252
252
2.7
2.8
4.9
10.6
11.4
8.7
31.2
32.4
40.7
e12.2/e12.2b e14.2/e14.2b e22.2/e22.2b e33.2/e33.2b
1.7
1.8
2885
2868
31.2
32.4
a r m s t r o n g f lu i d t e c h n o lo g y. c o m
e33.2/
e33.2b
252
7.9
6.3
42.1
220-240vac
220-240vac
2.3
2.3
2780
2760
40.7